R, s, what is the difference between several thermocouple type B specific _ instrument
R, s, what is the difference between several thermocouple type B specific _ instrument
by:JVTIA2020-10-29
Platinum rhodium - 13
Platinum R type thermocouple platinum rhodium - 13
Platinum R type thermocouple for precious metals thermocouple.
Accidentally wire diameter provision of 0.
5 mm, allowable deviation -
0.
The positive (015 mm,
RP)
In the name of the chemical composition of platinum rhodium, contain the rhodium is 13%, platinum-based is 87%, the cathode (
RN)
For pure platinum, long-term use of temperature is 1300 ℃, short-term use temperature is 1600 ℃.
R type thermocouple in the thermocouple series has high accuracy, stability, best measure [area wide, long service life, etc.
Its physical and chemical performance is good, the thermoelectric potential stability and oxidation resistance at high temperature is good, suitable for oxidizing and inert atmosphere.
R type thermocouple deficiency is thermoelectric potential, thermoelectric potential rate is small, low sensitivity and mechanical strength under high temperature to drop, is sensitive to pollution, precious metal materials is expensive, and one-time investment is larger.
Platinum rhodium - 10
Platinum S type thermocouple platinum rhodium - 10
Platinum S type thermocouple for precious metals thermocouple.
Accidentally wire diameter provision of 0.
5 mm, allowable deviation -
0.
The positive (015 mm,
SP)
In the name of the chemical composition of platinum rhodium, contain the rhodium is 10%, platinum-based is 90%, the cathode (
SN)
For pure platinum, commonly known as single platinum-rhodium thermocouple.
The temperature is 1300 ℃, the long-term use of thermocouple short-term use temperature is 1600 ℃.
S type thermocouple in the series of thermocouple with high accuracy, stability, best to measure your area wide, long service life, etc.
Its physical and chemical performance is good, the thermoelectric potential stability and oxidation resistance at high temperature performance is good, suitable for oxidizing and inert atmosphere.
S type thermocouple deficiency is thermoelectric potential, thermoelectric potential rate is small, low sensitivity and mechanical strength under high temperature to drop, is sensitive to pollution, precious metal materials is expensive, and one-time investment is larger.
Platinum rhodium - 30
Platinum rhodium 6 B type thermocouple platinum rhodium - 30
Platinum rhodium 6 B type thermocouple for precious metals thermocouple.
Accidentally wire diameter provision of 0.
5 mm, allowable deviation -
0.
The positive (015 mm,
英国石油公司(BP)
In the name of the chemical composition of platinum rhodium, contain the rhodium is 30%, platinum-based is 70%, the cathode (
BN)
For platinum rhodium, rhodium for content 6%, therefore, commonly known as the dual platinum-rhodium thermocouple.
The temperature is 1600 ℃, the long-term use of thermocouple short-term use temperature is 1800 ℃.
B type thermocouple in the thermocouple series has high accuracy, good stability, test your area wide, long service life, high temperature limit, etc.
Suitable for oxidation and inert atmosphere, can also be short term used in vacuum, but does not apply to reducing atmosphere or containing metal or nonmetal steam atmosphere.
B type thermocouple is an obvious advantage don't need a compensation for the compensation conductor, because in the range of 0 ~ 50 ℃ and internal potential less than 3 mu V.
B type thermocouple deficiency is thermoelectric potential, thermoelectric potential rate is small, low sensitivity and mechanical strength under high temperature to drop, is sensitive to pollution, precious metal materials is expensive, and one-time investment is larger.