The specifications of the air outlets under various types of air outlet modes can be selected according to the application. Then, according to the air supply volume and air supply speed requirements, the number of air outlets can be calculated according to the following formula: Qu003d3600V × S × n V— - Air supply speed (m/s) Q - Air supply volume (m3/h); S - Area of u200bu200ba single air supply port (m2); n - The number of various types of air supply ports on the pipeline.