loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

10 points for attention when configuring air cooler ducts

Professional air duct installation can ensure the performance and life of the system and the aesthetics of the entire system, which is a necessary guarantee for the quality of the final system. Professional debugging can make up for the problems caused by the changes between the original design and the actual situation on the spot. The 10 points for attention when configuring the air cooler duct are as follows: 1) The material of the air supply duct is generally galvanized sheet (commonly known as tinplate). It can use glass fiber reinforced plastic, plastic duct, fiber fabric duct. Alias: cloth duct, cloth bag duct, fabric cloth duct, fiber fabric duct, etc. 2). The air supply outlet is set in the place where cooling is actually required. The design air volume of the air outlet is the air volume required for the place to be cooled. The specifications of the air outlet can be determined according to the air volume and the wind speed of the air outlet. The material of the air outlet can be plastic or aluminum. Alloys and other products, the air outlet nozzle type can be used in various ways according to the actual situation. The fiber fabric cloth air duct does not need to install an additional air outlet. The uniform flow rate of the air outlet throat is controlled at 3-6m/s (recommended to adopt 4-5m/ s flow rate). 3) The length of the air supply duct should be designed according to the different characteristics of the air pressure of different types of environmentally friendly air conditioners. 4) Generally, the designed air duct is economical and can reach the lowest wind resistance and noise, so that the air supply of the air cooler can reach the maximum value. The bending radius of the air duct is generally not less than twice the diameter of the air duct to reduce Resistance of elbow ventilation. 5) The specifications of the air supply ducts are generally designed by the assumed flow velocity method. The main ducts are kept at 8-10m/s, the branch ducts are 6-8m/s, and the end ducts are kept at 4-6m/s. 6) The designed pipeline should be as straight as possible to prevent unnecessary bends and branch pipes in order to reduce the resistance of the pipeline. 7). Consider from the perspective of layout and economy. Where ducts are not needed, ducts are not needed. Where ducts must be used, the ducts should be designed as short as possible. 8). Longer pipes are designed into multiple sections of air ducts with different specifications according to the air volume, and the reducer pipes are used for connection. The setting of reducer pipes should not be too many. Normally, the whole pipe does not exceed four. The length of the reducer pipe is 2 (Dd). Decided (because there is a PAD regulating valve in the air distribution pipe, so there is no need to reduce the diameter). 9). If there is a branch pipe in the design, a valve or air distribution baffle must be installed on the branch pipe to adjust the air volume so that the branch pipe air volume reaches the design value. 10) The connection between the air supply pipe and the air outlet of the air cooler should be sealed; the outdoor pipe should be designed for heat preservation if it is too long, and the indoor pipe generally does not need heat preservation. The above-mentioned views all represent the viewpoints of the air distribution duct installation staff who have been summed up from the experience of installing air cooler ducts over the years, but the setting of the ducts should also be done in different ways according to different environments.

Shanghai Jiutian Automation Equipment Co., Ltd 's products comply fully with all compatible producing regulations.

Buy temperature sensor RTD supplier products online from China at the best price from here Jiutian Temperature Products.

The stability of the system, controllability of the temperature sensor manufacturers process, and mobility of the machines provide with a flexible and reliable resistance temperature detector system.

If our brand is successful and consistent, it will be much easier to initially grab customers and encourage them to purchase temperature sensor further.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect