loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

4-20mA output PT100 Temperature sensor with transmitter 1
4-20mA output PT100 Temperature sensor with transmitter 2
4-20mA output PT100 Temperature sensor with transmitter 3
4-20mA output PT100 Temperature sensor with transmitter 4
4-20mA output PT100 Temperature sensor with transmitter 5
4-20mA output PT100 Temperature sensor with transmitter 1
4-20mA output PT100 Temperature sensor with transmitter 2
4-20mA output PT100 Temperature sensor with transmitter 3
4-20mA output PT100 Temperature sensor with transmitter 4
4-20mA output PT100 Temperature sensor with transmitter 5

4-20mA output PT100 Temperature sensor with transmitter

    oops...!

    no product data.

    Go to homepage
    Certification
    CE
    Availability
    OEM, ODM, OEM/ODM
    Delivery Time
    5 working days
    Start Port
    Shanghai, China
    Supply Ability
    Manufacturer

    4-20mA output PT100 Temperature sensor with transmitter

    Specifications:

     Product name

    RTD

    Model NO

    WZP-325

    Generation mark

    PT100

     Probe diameter

    Φ6/8mm

    Fixed type

    Thread

    Probe length

    100mm or customized


    4-20mA output PT100 Temperature sensor with transmitter 6

    4-20mA output PT100 Temperature sensor with transmitter 7

    4-20mA output PT100 Temperature sensor with transmitter 8

    Installation note

    1. The thermal resistance should be mounted vertically on the horizontal or vertical pipe as much as possible.

    A protective sleeve should be installed for easy access and replacement.

    2. When measuring the temperature inside the pipe, the length of the component should be on the center line of the pipe (ie, the insertion depth of the protection pipe should be half of the pipe diameter).

    3, when the temperature dynamic table is installed, the opening size should be appropriate, the installation should be beautiful and generous.

    4. Use high temperature resistant cable or high temperature compensation line in high temperature zone.

    5. Select different measuring components according to different temperatures. Generally, the thermal resistance is selected when the measured temperature is less than 400 °C.

    6, the wiring should be reasonable and beautiful, the needle indication should be correct.


    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data

    CONTACT DETAILS

    Phone: +86 13816377866
    Email: jimmy011@126.com
    Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
     

    CONTACT US FOR FREE SAMPLE !

    For more products related question ,Welcome to inquiry us .

    Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
    Customer service
    detect