loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

485 first company of service of manufacturer of alternating current temperature sensor

Using the current temperature sensor are places which need to pay attention to?

* pay attention to the auxiliary power supply information on product labels, the temperature sensor of auxiliary power level and polarity is wrong, otherwise will damage the temperature sensor;

* current direction and shell be the same as the arrow marked on the products, to achieve positive output;

* the original edge bus should not exceed 60 ℃, the temperature of current bus when threading hole to fill the original edge, obtain better measurement accuracy;

* this series of temperature sensor is not set internal lightning protection circuit, when the temperature sensor input, output, feeder exposed to outdoor environment of the bad weather, lightning protection measures should be paid attention to;

* temperature sensor is integrated structure, sealed, avoid collision and fall at the same time.

current temperature sensor - — Electromagnetic compatibility

electromagnetic compatibility EMC, ( 电- - - - - - 磁兼容性) Is the study of electrical and electronic equipment that can perform their respective functions in common electromagnetic environment state of coexistence, the requirements of the various devices in the same electromagnetic environment can work normally and noninterference, achieve 'compatibility' state a discipline. The deterioration of space electromagnetic environment is more and more easy to make electronic components caused by incompatible between false action in the system, so the electrical and electronic equipment electromagnetic compatibility testing is very necessary. Due to the urgent needs of the actual production, scientific research and marketing, has passed the electromagnetic compatibility test a consensus has emerged among current and voltage of temperature sensor, and has become a compulsory standards.

current temperature sensor output

current temperature sensor using the output type depends on the application and operating environment.

- analog voltage signal The temperature sensor output analog voltage signals. - analog current level The temperature sensor output analog current signal. It can be used for signal transmission standard 4 - 20mA。 - switch and the voice signal Temperature sensor can be connected to the switch or voice alarm, the alarm by noise or process changes indicate current levels. - modulation frequency output Current temperature sensor can output the following list of any frequency output. Sine wave pulse train amplitude modulation ( AM) FM ( FM) Pulse width modulation ( 脉宽调制)

USES current temperature sensor module note

current temperature sensor will direct current voltage power frequency signals, such as isolation into a 4 - 20mA/0- 10 v, etc all kinds of standard signal on both ends of the semiconductor chip to control the current I, and applying magnetic induction intensity in the vertical direction of the wafer for B and strong magnetic field, is in the direction perpendicular to the current and magnetic field, will produce the electric potential difference as UH voltage.

when measuring current, the use of single wire temperature sensor module aperture, in order to get a better dynamic performance and sensitivity.

the better accuracy of the temperature sensor module was measured under rating, when measured value is lower than the rating, the original with many winding coils, the total ampere turn close to the rating, in order to gain a better measurement accuracy.

when use current temperature sensor module, vice side should be connected to the power supply, then turn on the primary side current or voltage. Current bus temperature shall not exceed 100 degrees.

when choosing temperature sensor module, according to the measuring range, accuracy, reaction time and the parameters such as connection mode, choose different models of temperature sensor.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect