loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

Bimetallic thermometer in what problems may arise in the process of installation and debugging

Bimetallic thermometer during the process of installation and debugging, what are the possible problems and how to solve? Transmitter output. Have encountered this kind of circumstance to see the power of the transmitter to reverse, if meet the, to connect power supply polarity can be correctly; Measurement transducer power supply, check whether there is a 24 v voltage, transmitter power is greater than 12 v, if there is no power supply, check whether the circuit break line, testing instrument have selected error and so on; If it's with a header, check whether the header is damaged, if is a problem of header, it is ok to replace. Check whether the power is in the transmitter power input; Take the power cord on the power supply terminals. Transmitter output is less than 20 ma, check whether the power of the transmitter is normal, if less than 12, will check whether there is a big load in the circuit, the input impedance of transformer load to conform to the transmitter power supply voltage; Whether the actual pressure more than pressure transmitter of the selected range, to choose appropriate range of pressure transmitter. If the pressure sensor is damaged, serious overload can damage isolation diaphragm, this time need to send back the manufacturer to repair; Connection is loose, broken line and tight; The power line connection is correct, the power cord to connect on the corresponding terminal. Problems of the bimetallic thermometer, we need to understand some simple processing method, that it doesn't appear problem when the controls.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect