loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

Compensation conductor index number and polarity judgment _ instrument

We know that the compensating conductor is the extension of the reference junction of the thermocouple, have the effect of mobile reference end position, extending the reference side temperature should be a constant or with itself has reference end temperature automatic compensation device, otherwise still may be due to the new reference measurement error caused by the temperature variation. Reliable testing method is commonly used, is to compensate the ends of the wire stripping insulation layer, the two wire twisted together to make the hot end of thermocouple, into the boiling water, two at the other end of the wire are connected to the dc potentiometer ( Should not be connected to the moving coil direct reading mV table, for measuring take the current when it is low) , the measured thermoelectric potential compared with table 1, and relatively close to that of compensation wire index number, depending on the potentiometer is the cathode can be determine the polarity of the compensating conductor. Due to the test by the compensating conductor when the temperature of the reference junction of the thermocouple is not necessarily the 0 ℃, is 20 ℃, for example, the thermoelectric potential is measured under reference end thermoelectric potential value of 0 ℃. In some unknown degree, compensating lead wires, for example, such as reference end temperature 20 ℃, measured values such as in 3. 928±0. 150 mv range, can determine the compensating conductor index number is K. 3. 928 K is dividing thermocouple 100 ℃ and 20 ℃ thermoelectric potential difference, 0. Number is 150 K dividing common compensation conductor should be tolerance. The location of the compensating conductor dashboard connection point for early match the moving coil instrument thermocouple, five Ω, 15 Ω two line resistance requirements, when the thermocouple installation location far away from the moving coil table, or by dividing number K, N, E, J, T contains copper and nickel materials such as compensating lead wires, the line resistance is bigger, use should pay attention to when choose larger section compensating lead wires. Such as selecting an external 15 Ω line resistance E index number of the moving coil instrument, its with compensating conductor cross-section of 1. 0 mm2、2. 5 was, and the corresponding unit length line resistance 1 respectively. 25 Ω/m and 0. 5 Ω/m, the compensating conductor big for only 12 m and 30 m in length. If you don't pay attention to when designing, the length more than easily, cause measurement error. When thermocouple compensation conductor should be introduced into digital display instrument, if the receiving terminal display device, and display device terminals and instrument between terminals with copper wire connection, due to the difference in temperature will cause measurement error. So good compensation wire across the terminals of the instrument panel will be directly connected to the instrument of the terminals. Such as wiring in the digital display instrument, due to the commonly used in tray display, recorder itself for electricity and heat, make its terminal point temperature is higher than the temperature of the display device terminals.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect