loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

Compensation conductor should be use to guide _ instrument

Method of commonly used has the following several kinds of freezing temperature compensating conductor thermoelectric potential correction coefficient method of the cold end temperature compensator method p-n junction compensation method cold end extension method. One s type thermocouple measured thermoelectric potential is 2934 mu V, the cold end temperature of Tn = 30 oc, strives for the measured temperature T. Solution: check the EAB ( 30, 0) =1203μVEAB( T, 0) =EAB( T, 30) +EAB( 30, 0) = 2934 + 1203 = 4137 mu V look-up table the EAB ( T, 0) =4137μV,T=101oC. When the temperature of the cold end To = Tn To 0 oc, as long as Tn constant, known by fixed a EAB ( Tn,0oC) , transfer the measured value to the cold end temperature of 0 o the thermoelectric potential of C. Connect with the free cod of a s type thermocouple should be convenient and reliable; Protect casing thermal electrode should ensure sufficient isolation and harmful medium. Two hot electrode welding of thermocouples must be strong; Two hot electrode should be well insulated between each other, prevent short circuit; Non-standard thermocouple or on the order of magnitude less than the range using standardized thermocouple, generally no unified indexing table, mainly used in some special occasions. S type thermocouple cold end temperature compensation as a result of the thermocouple materials are generally more expensive ( Especially when using precious metals) And temperature measuring points are far away the distance to the instrument, and in order to save thermocouple materials, reduce cost, usually adopt the compensating conductor (of the cold junction of the thermocouple The free end) Reaches to the relatively stable control indoor temperature and connected to the meter terminals. It must be pointed out that the role of the thermocouple compensation wire only extend thermal electrode, make moves to the control room of the cold junction of the thermocouple meter terminal, it itself does not eliminate the cold end temperature change on the influence of temperature, no compensation. A variety of s type thermocouple relationship between temperature and thermoelectric emfs indexing table is made in the cold end temperature is zero, therefore, when using a thermocouple temperature measurement, if you want to direct application of thermocouple indexing table, you must meet the t0 = 0 ℃ condition. In this way, not only is not 0 ℃, and is not a constant, because the t0 this would introduce errors. Eliminate or can the error compensation method.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.