Expert Thermocouple & RTD &Temperature Sensor Manufacturer.
Differential pressure transducer is used to prevent the medium directly into the transmitter in the pipeline pressure diaphragm between the transmitter and capillary connected by the filled with fluid. It is used to measure the liquid level of liquid, gas or steam, flow and pressure, and then transform it into 4 ~ 20 ma DC signal output. 1 ek magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
the differential pressure transmitter take pressure tube is there any requirement? 1 ek magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
( 1) In order to avoid the differential signal distortion during transmission, should take nearly guide pressure tubes was laying. 1 ek magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
( 2) Guide pipe should be kept between the vertical or horizontal plane into not less than the slope of 1:12, bend should be evenly rounded corners. 1 ek magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
( 3) Guide pipe should not be influenced by external heat source, capacitance pressure transmitter and pay attention to heat preservation. If add heat tracing, to avoid overheating, in order to avoid liquid gasification, produce false differential pressure. 1 ek magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
( 4) Longer guide pressure tube. Should be in high and low respectively installed gas collector and exhaust valve, the settler and drain valve, magnetic flap 1 ek | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
( 5) Guide the inner diameter of the pipe should be according to the nature of the medium. Generally is 10 ~ 13 mm, minimum shall not be less than 6 mm. The length of the best within 16 m. 1 ek magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
( 6) Guide in the pressure tube should be equipped with the necessary cutting, flushing, sewage, such as valve; 1 ek magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
with magnetic flap thermometer thermometer copyright disclaimer: 1 ek magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
(1) all this indicate & quot; Source: & other; Jiangsu thermometer factory automation & throughout; All works, the copyright belongs to jiangsu thermometer factory automation instrument co. , LTD. , must be reproduced please indicate jiangsu thermometer factory automation instrument co. , LTD. , the WWW. 517席。 com。 Violators we will pursue relevant legal responsibility 1 ek magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
1 ek magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
1 ek magnetic flap | | glass thermometer thermometer floating ball thermometer | | double color glass thermometer thermometer
CONTACT DETAILS
Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
CONTACT US FOR FREE SAMPLE !
For more products related question ,Welcome to inquiry us .