loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

Factors Affecting Thermocouple Response Time

1. The structure and size of the thermocouple. The thicker the diameter of the thermode and the maintenance tube, the greater the laziness; the thicker the tube wall, the greater the laziness. In this way, the longer the thermocouple reaches stability, the longer the response time. 2. Different materials have different thermal conductivity. For example, the metal protection tube conducts heat better than the porcelain protection tube, the heat is less lazy, and the time for the thermocouple to reach stability is shorter, that is, the response time is short. 3. The response time is also different with the change of the working conditions, that is to say, the response time of the thermocouple with the same structure is different under different heat exchange conditions. When the temperature shows a step change, the time required for the output of the thermocouple to change to a certain regular percentage of the step change is called the thermal response time of the thermocouple, usually indicated by T. 2. The temperature range of the two sensors is different. The thermal resistance usually checks the temperature range of 0-150 degrees, and the maximum measurement range can reach about 600 degrees (of course, it can check the negative temperature). 3. From the point of view of material, thermal resistance is a kind of metal material, which has a temperature-sensitive change of metal material, and thermocouple is a bimetal material, that is, two different metals, due to the change of temperature, in two different metal wires There is a potential difference between the two ends. 4. The input modules of the thermal resistance and the thermocouple corresponding to the PLC are also different. This sentence is no problem, but usually the PLC is directly connected to the 4-20ma signal, and the thermal resistance and the thermocouple usually have a transmitter. Only connected to the PLC. If you connect to DCS, you don't need to use a transmitter! Thermal resistance is RTD signal, thermocouple is TC signal! 5. PLC also has thermal resistance module and thermocouple module, which can directly input resistance and galvanic signals. 6. Thermocouples are of J, T, N, K, S and other types. Rosemount temperature transmitters are more expensive than resistance, and some are cheaper than resistance, but including compensation wires, the cost of thermocouples is high.

Shanghai Jiutian Automation Equipment Co., Ltd is recognized as one of the leading manufacturer of in China.Trust in us and make Shanghai Jiutian Automation Equipment Co., Ltd your resistance temperature detector supplier. Our products will bring more economic value to you.

To know more about and the market trends, go to Jiutian Temperature Products.

As the full potential of temperature sensor manufacturers lies in , the demand for is increasing globally, and is being adopted across the global market.

temperature sensor can be applied in different ways as RTD supplier.

Shanghai Jiutian Automation Equipment Co., Ltd has extented its range of manufacturing scale, which satisfys customers' needs.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect