Expert Thermocouple & RTD &Temperature Sensor Manufacturer.
1. Large space. The three-dimensional elevated warehouse is a tall and large space building, and its dimensions are larger than general buildings in the height direction, or the horizontal length and width directions. This large space size brings inconvenience to the air distribution of the central air-conditioning system, and the conventional top air supply, side air supply and jet air supply are difficult to meet the requirements. 2. The internal space is completely occupied by the racking and stacker operation process space. It is difficult for the air-conditioning return air duct to reach into the central area of u200bu200bthe internal space of the elevated warehouse, and the return air ducts are also difficult to match, so it is still difficult to ensure uniformity in the elevated warehouse. The temperature and humidity field. 3. The entire internal space belongs to the controlled air-conditioning area. Because the high-bay warehouse may also store materials on the top layer of the shelves, the controlled air-conditioning area of u200bu200bthe high-bay warehouse is almost from the top to the ground. Therefore, it is determined that the elevated warehouse must maintain the uniformity of the temperature and humidity field regardless of whether it is in the vertical direction or the horizontal direction. 4. The wind speed in the internal space should not be too high. Because some of the materials stored on the shelves are open, excessive wind speed will easily blow off the materials on the surface of the storage box. 5. The uncertainty of material storage. The storage quantity of materials on each shelf comes from production requirements, and it may be full or empty. The air distribution of the air conditioner should adapt to this characteristic. 6. The heat and humidity load of the air conditioner is not large. Because the materials stored in the overhead storage produce almost no heat and moisture, the main heat and moisture load comes from the enclosure structure and the heat dissipation of the stacker crane. Generally, the illuminance in the overhead storage is relatively low, and the lighting heat dissipation is also very small. Therefore, the heat and humidity load in the elevated warehouse has no obvious particularity. 7. There is a temperature gradient in the elevated warehouse. 8. The enclosure structure is tight. Pudding Textile conducts in-depth research on the above-mentioned characteristics of the elevated tobacco warehouse. The permeable fiber fabric air duct combines 7 air supply modes for CFD simulation to determine a set of ventilation schemes suitable for the elevated warehouse.
Shanghai Jiutian Automation Equipment Co., Ltd has an array of branches in domestic for servicing customers with high-quality products.
Shanghai Jiutian Automation Equipment Co., Ltd provides which will help you RTD supplier in a durable and reliable way. To learn more, go to Jiutian Temperature Products.
The rising temperature sensor manufacturers consciousness observed worldwide are expected to be key factors driving the demand for RTD supplier resistance temperature detector.
need fuel for energy,while temperature sensor manufacturers do not.
There are many advantages associated with .
CONTACT DETAILS
Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
CONTACT US FOR FREE SAMPLE !
For more products related question ,Welcome to inquiry us .