How much do you know about air duct installation specifications?

What needs to be done before installation: 1. The construction of the building envelope is completed, all obstacles and sundries have been removed, and the ground sundries have been removed! 2. When installing the air duct of the purification system, the floor of the installation components inside the building has been prepared, and the concrete on the wall has been leveled. It must be carried out under the condition that the room is free of dust or dust-proof measures. 3. The auxiliary materials at the installation site must be complete, and there must be quality and technical guidance from construction technicians. Precautions for the installation of air ducts: 1. It is strictly forbidden for other pipelines to pass through the air duct. 2. The air duct installed in the flammable and explosive environment should be well grounded, and the air duct passing through the living area or production area must be installed tightly and not Device air duct interface. 3. The fixing of the outdoor vertical air duct shall not be connected with the lightning rod or the lightning protection facilities of the house. 4. The installation of air ducts must comply with the following technical regulations: ① The configuration of the connection between air ducts and ventilation equipment and accessories shall not reduce the connecting pipes of the connecting parts. ②The hanger can not be set at the air outlet, air valve, inspection door and automatic control mechanism, and must not be fixed on the flange to avoid the deformation of the air duct affecting the function of the air duct. ③The installation of the hanger must comply with the corresponding installation regulations. The suspended air ducts and components should be provided with fixed points to prevent swinging, such as fixed brackets, supports, etc. The location and number of fixed points should be determined according to the system conditions. Fabric duct ventilation duct ④ Flange padding and thickness According to the different conveying air temperature, the material selected is also different. ⑤When the air duct and components pass through the wall or roof, a rain cover should be installed. When the air duct passing through the roof exceeds 1.5m, the cable should be pulled. The cable should be galvanized or wire rope. The cable should not be fixed on the air duct flange. , It is strictly forbidden to pull on the lightning rod or lightning net. ⑥ The installation of the flexible short pipe should be moderately tight and not twisted. The length of the flexible metal or non-metal flexible air pipe installed in the ventilation duct should not exceed 2m, and there should be no dead bends and slumps. ⑦The support and hanger of the thermal insulation duct should be located outside the thermal insulation layer, and the thermal insulation layer should not be damaged.

Shanghai Jiutian Automation Equipment Co., Ltd has created its reputation on a commitment to manufacturing high-quality products and services while satisfy the needs of customers.

Shanghai Jiutian Automation Equipment Co., Ltd also values the time, skills, and expert opinions of our staff. We are committed to providing fair and living wages, reasonable, structured work schedules, and clear duties and spheres of rights and responsibilities for each team member.

We utilize our expertise to develop services that add value at each phase of theresistance temperature detector development cycle. We evaluate and implement new strategies in response to changing customer profiles and market conditions.

The success of temperature sensor of campaigns largely rides on how you market your company to the crowd.

temperature sensor manufacturers needs not be tedious anymore with the application of . So getting the right resistance temperature detector can drastically promote RTD supplier.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.