loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

How to clean the differential pressure transmitter

After the differential pressure transmitter is installed in the industrial site and used for a period of time, sediment or foreign matter will accumulate in the pressure pipeline of the instrument and the transmitter to varying degrees, which may block the pipeline of the pressure measuring instrument or cause measurement errors. In order to maintain the accuracy of the differential pressure transmitter and obtain satisfactory performance, the differential pressure transmitter and pipeline must be cleaned regularly. 1. Under normal circumstances, cleaning the differential pressure transmitter should be carried out in the following numbering order: (1) Close the high-pressure side conduit stop valve and differential pressure transmitter of the high-pressure side stop valve of the three valve groups. (2) Confirm that the balance valve is closed. (3) Close the low-pressure side pressure conduit shut-off valve and the low-pressure side shut-off valves of the three valve groups. (4) Slowly open the vent plug to relieve pressure. (5) Open the high-pressure side shut-off valve of the three valve groups and the shut-off valve of the high-pressure side conduit. (6) Open the pressure equalizing valve and purge the pipeline with the exhaust plug on the high pressure side. (7) Close the balance valve, the shut-off valve on the high-pressure side of the three valve groups and the shut-off valve on the high-pressure side of the pressure conduit. (8) Open the low-pressure side shut-off valve of the three valve groups and the shut-off valve from the low-pressure side to the pressure pipe. (9) Open the pressure equalizing valve and purge the pipeline with the low pressure side exhaust plug. (10) Close all valves and operate the differential pressure transmitter as normal. 2. If the inside of the differential pressure transmitter needs to be cleaned, please follow the following sequence: (1) Remove the hexagonal bolts used to clamp the pressure transmitter chamber cover, and remove the pressure transmitter chamber cover. (2) Clean the diaphragm and chamber cover with a soft brush and solvent. At this time, care should be taken not to deform or damage the transmitter diaphragm. (3) When reinstalling the transmitter housing cover, you can replace the gasket with a new one as needed. (4) The bolts and transmitters used for clamping the chamber cover should be assembled according to the specified tightening torque.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect