How to correctly install the explosion-proof heat resistance?

Users in the installation of explosion-proof heat resistance, in order to ensure the using quality of late, so we must be sure to pay attention to some problems. Usually, for the installation requirements of explosion-proof heat resistance has: is advantageous to the temperature measurement accuracy, safety and reliability, convenient maintenance, and shall not affect the equipment operation and production operations, etc. So, we are in the process of actual installation, how to grasp these points?

in fact, if you want to meet these requirements, so we choose the installation location, needs to be more careful. Below together to get to know the specific content. In order to make the measurement of thermal resistance and capable of achieving the full heat exchange between measured medium, you need to select the appropriate measuring point position, don't choose near the valve, or the position such as elbow and pipe.

in addition, in order to prevent causing more energy loss, as far as possible to reduce the error, we should also ensure that heat resistance with enough insertion depth. If is fluid temperature measuring pipe center, is the measuring end is inserted into the pipe center; And if the current body of pipe diameter is 200 mm, so should keep its insertion depth at 100 mm.

in addition, we also need special consideration to the work environment conditions, such as if it is to measure some of the high temperature and high pressure and high velocity, so we must as far as possible to reduce cases of fluid resistance, so this time can choose protection tube shallow way, or is the use of hot shell heat resistance. Usually, the inserting depth of the former shall not be less than 75 mm, the latter is a standard insert depth should be 100 mm.

of course, at the time of actual installation, there are many problems we need to consider, hope everyone can seriously and properly installed thermal resistance, so in the later use of time, not only can guarantee the use effect, but also can avoid a lot of trouble.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.