How to distinguish the thermocouple _ instrument

Working principle of the thermocouple is closed loop by the two different conductor material composition, when both ends exist when the temperature of the ladder, can produce a loop, and there will be an electric current passes through the loop, while the existed between the electrical energy on both ends, and that this power is called thermoelectric emf, this is called the seebeck effect, seebeckeffect) 。 Thermocouple method to distinguish two different conductor material is hot electrode, and here, if the temperature is high, the normal work of the end for end, on the contrary, the other end of the low temperature is the free end, usually under the condition of free end, he is under a state of constant temperature. According to the thermoelectric emf as a function of temperature, the thermocouple indexing table; Indexing table is free end temperature at 0 ℃, under the condition of different thermocouples with different indexing table. Thermocouple of the whole circuit, if access to a third metal materials, and the material when the temperature of the two contact, generated by the thermocouple thermoelectric is set to remain the same, which is not affected by the third metal access in the loop. Therefore, when the thermocouple temperature measurement, can be connected to the measuring instrument, measured after the thermoelectric emfs, can know the temperature of the measured medium. Thermocouple measuring temperature to the cold end ( Measure the end for the hot end, by the end of the lead connected to the measurement circuit is called cold junction) Temperature remains constant, the size of thermoelectric potential and measured temperature in certain proportion relationship. When measuring, the cold end ( Environment) Temperature changes, will seriously affect the accuracy of measurement. Take action at the cold end compensation due to the impact of the cold end temperature change is called the thermocouple cold junction compensation is normal. Connected to the measuring instrument with special compensation conductor. K type thermocouple is above 500 ℃ of dosage big metal thermocouple temperature measurement area, its usage is the sum of other metal thermocouple. Thermocouple how is negative what are negative to the positive ( kp) In the name of the chemical composition is: ni: cr material 90:10, the cathode ( kn) The chemical composition is: ni: si material 97 k type thermocouple linearity, thermoelectric emfs, larger so can be used for oxidizing, inert atmosphere. But k type thermocouple cannot be directly used for sulfur, reducing or at high temperature reduction, oxidation atmosphere and vacuum alternately, is also not recommended for people with weak oxidizing atmosphere. It is very nickel-chromium alloy (containing 10% chromium kp) , the negative is extremely containing silicon 3% nickel silicon alloy ( kn) 。 Therefore, thermocouple how points are negative, based on this feature, use the magnet can be easily identified thermocouple of positive and negative pole.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect