In order to ensure the accuracy of the thermal resistance measurement, prolong the service life of thermal resistor, the following points should be paid attention to when using thermal resistance: ( 1) According to the temperature measurement range and temperature measuring medium, reasonable choose heat resistance; ( 2) According to the actual situation of measurement conditions, reasonable selection of thermal resistor insertion depth; ( 3) Using thermal resistance temperature measurement, reading measurements should be within the prescribed period of time; ( 4) Should be paid attention to in the measurement of dynamic temperature, select the appropriate time constant of the thermal resistance; ( 5) In order to reduce the measurement of electric current produced by natural phenomenon, should be within the scope of current control zha the following: the use of standard platinum thermal resistance current should not be more than 1 ma; The use of industrial heat resistance current should not exceed 6 ma.