loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

Installation Instructions for Air Ducts and Support Hangers in Ventilation Ducts - Galvanized Ducts

In the ventilation duct, in addition to the air duct, there are also some accessories such as hangers, so its installation is divided into two parts, one part is the air duct, including spiral air ducts, rectangular air ducts, etc., and the other part is the hanger , the following two parts will be introduced in detail. 1. Air duct (1) The air duct should be installed after the construction of the building envelope is completed and the site is cleaned up. (2) Before installing the air duct, the position, elevation and direction of the air duct should be reviewed. To meet the design requirements, the position of the reserved hole should be correct, and the size of the hole should be larger than the outer dimension of the air duct by 100mm or more. (3) When handling the air duct, avoid collision or beating, so as not to damage the air duct. Dust and debris should be cleaned up before installation. If there is a pause during installation, the air duct opening should be closed to prevent dust and foreign objects from entering the air duct. (4) The interface of the air duct cannot be installed in the wall or floor, and pipes, wires and cables cannot be laid in the air duct. (5) If the air duct is transporting flammable and explosive gas, or in such an environment, necessary grounding measures should be taken for protection; if it is transporting air with a temperature higher than 80 °C, necessary protection should be taken measure. (6) There should not be seams at the bottom of the air duct, if so, it should be sealed. (7) If the air duct is to pass through the floor or wall, the embedded pipe or protective casing should be used, and there should be a flexible material between them for sealing. (8) When the air duct is connected with the equipment, there should be a flexible short pipe at the connection, with a length of 150-300mm, or the specified length. (9) The position of the air duct measuring hole should be selected in the area where no eddy current is generated, and it should be easy to measure and observe. 2. Support and hanger (1) All accessories of the support and hanger, the use of materials used, should meet the design requirements and parameter requirements. (2) Under the larger allowable installation distance of the air duct, the minimum specification of the hanger should meet the regulations. (3) The embedded parts of the support and hanger should be installed correctly, and should be firm and reliable. The embedded part should be cleaned, and the exposed part should be treated with anti-corrosion. (4) The support and hanger should not be located in the operation part of the equipment. When fixing the support and hanger, the expansion anchor bolts should be used for fixing, and the use of the expansion anchor bolts should meet the specified requirements.

Shanghai Jiutian Automation Equipment Co., Ltd has created its reputation on a commitment to manufacturing high-quality products and services while satisfy the needs of customers.

As a result, consumers will reward JVTIA with leadership sales, profit, and value creation, allowing our customers in which we live and work to prosper.

You can get more information from Jiutian Temperature Products for on sale. welcome to visit us and send your inquiry!

By investing in an ethical supply chain, Shanghai Jiutian Automation Equipment Co., Ltd position ourselves to engage with a driven, engaged customer base.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect