Introduce the installation specifications and standards of each part of the ventilation duct

Fabric air duct ventilation ducts, fabric air duct ventilation ducts, ventilation duct manufacturers will give you a detailed introduction to the installation standard specifications for each part of the duct. 1. The installation of the air duct should meet the specifications. 1. Other pipes in the air duct shall not pass through; 2. The air duct system containing flammable and explosive gas or installed in flammable and explosive environments should be grounded. When passing through the living area or other auxiliary production rooms, it should be Keep hermetic, no ports. 3. The air duct whose conveying air temperature is above 80 degrees Celsius should be protected according to the design requirements. 4. The fixed cable of the outdoor riser is strictly prohibited to be pulled on the lightning rod or on the wire. 2. The installation of pipe components must meet the following requirements: 1. The installation of various pipe fittings and operating mechanisms should ensure their normal use function and easy operation; 2. When installing the oblique plate air valve, the valve plate must be upward Pull up; when installing horizontally, the valve plate should also be inserted in the direction of the airflow; 3. The installation direction of the check valve and the automatic exhaust valve should be correct. 4. The installation direction and position of fire dampers and smoke exhaust valves (ports) should be correct. The fire isolation valve is on both sides of the partition wall, and the distance from the wall surface shall not be greater than 200mm. 5. Manually install the sealing valve, the arrow on the valve must be consistent with the direction of the impact. 6. After the installation of the air duct system, the tightness inspection should be carried out according to the system category. The air leakage should meet the design requirements, and the air duct must be inspected or verified by manufacturability. Its strength and tightness requirements should meet the design or the following regulations: ① When the strength of the air duct meets the working pressure of 1.5 times, there will be no cracks in the joint; ② The allowable air leakage of the rectangular air duct should meet: low-pressure system air duct QL≤0.1056P0.65 Medium-pressure system air duct QM≤0.0352P0.65 High pressure In the formula of system air duct QH≤0.0117P0.65 QL, QM, QH——under the corresponding working pressure of the system air duct, the allowable air leakage per unit area of u200bu200bair duct per unit time [m3/(h m2)]; P— - Refers to the working pressure (Pa) of the air duct system. ③The allowable air leakage of low-pressure, medium-pressure annular metal ducts, composite ducts and non-metallic ducts in non-flange form shall be 50% of the specified value of rectangular ducts; ④The allowable air leakage of air ducts with brick and concrete structures It should not exceed 1.5 times the specified value of the rectangular low-pressure system air duct;

In the office, various are considered essential since they are used to achieve particular tasks in the office. Among these , resistance temperature detector, temperature sensor manufacturers, and RTD supplier are widely used.

No, this isn't a wonder product and it won't be likely to change your life but it will give your temperature sensor manufacturers a kick and bring the extraordinary to the every day. give it a shot at Jiutian Temperature Products.

While the productivity and efficiency benefits of automation are unequivocal for manufacturing temperature sensor, the need for skilled humans to operate, utilize and advance technologies is equally unmistakable.

resistance temperature detector is produced by Shanghai Jiutian Automation Equipment Co., Ltd ’s professional skills in high technology.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.