loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

K type thermocouple thermal response time?1

In the process of using the K type thermocouple will find the response time of K type thermocouple for the whole measurement process is very important, so the response time of the K type thermocouple should be how to measure? The K type thermocouple is measured by the project to introduce method of response time.

K type thermocouple measurement precision, wide measurement range. Because of thermocouple direct contact with the object being measured, not affected by intermediate medium.

K type thermocouple simple structure, easy to use. Thermocouple is usually composed of two different kinds of metal wire, but is not limited by the size and the beginning of, outside has protective casing, which are very convenient.

K type thermocouple measurement of the thermal response time is actually more complex, different test conditions will produce different measurement result, this is due to the effect of heat transfer rate of surrounding medium, heat transfer rate is high, the thermal response time is short.

in order to make the thermocouple comparable thermal response time, national standards: thermal response time should be in the special flow test device. Of flow velocity in the device should keep 04-005 ms, the initial temperature of 5 ℃ - Temperature 45 ℃, within the scope of the step value of 40 ℃ - 50℃。 In the process of test, the water temperature should be no greater than temperature step value plus or minus 1%. The subjects of the thermocouple placement depth of 150 mm in depth or design.

in the thermocouple thermoelectric potential near room temperature is very small, thermal response time is not easy to measure, so can use the same specification of national standard of the K type thermocouple electrode component to replace its own hot electrode components, and then tested.

test should record the change of the thermocouple output to the equivalent of 50% of the time temperature step change T05, when necessary record 90% 10% of the thermal response time T01 and changes of T09 thermal response time.

the thermal response time, recorded should be the same test at least three times the average of the test results, each measurement results for the average deviation should be within + / - 10%.

in addition, the time needed for forming temperature step change should not exceed one hundred percent of the test thermocouple T05. Record the ring should be time of instrument or instrument should not exceed one hundred percent of the participants thermocouple T05.

more high-quality sensors at https://www. rtdcn。 Com /

key words: thermal resistance, thermocouple, thermal resistance, platinum resistance, PT100, PT1000, pressure sensor and digital temperature sensor

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.