loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

K type thermocouple wiring, how to calibration, K type thermocouple the correct way to use

1, the K type thermocouple wiring?

if the thermocouple wiring accurate, temperature is accurate, if the connection is not accurate, will influence, the family of the thermocouple WenJinCheng measurement with the information, to stop the accurate temperature measurement, the entire process to stop the holding of the invalid. Especially the special places, to the accuracy of temperature measurement by the request is very high. In the category of temperature measurement on weekdays take thermocouple sensor to achieve. Thermocouple own existence economy, and the advantages of small measurement deviation.

thermocouple wiring has the branch is the cathode, through the process: the wiring board here are calibration: + and - , but also the manufacturer of the positive and negative, so much is need skills staff with lessons to conclude that

one, is to use color to distinguish, green for the anode, grey for the cathode

2, with a table is used to measure the

3, look at the temperature after wiring trend

4, if a magnet magnet also can be used to conclude that

5, make up the wire also need accurate wiring, there are positive negative

6, instrument, also should be careful of plus or minus points, terminal has marked below

general means as used in the thermocouple wiring terminals, due to the diversion of the daily in the terminal is made of common materials such as copper cathode copper, and constitute a thermocouple copper material difference, and the combination of general terminal blocks according to the difference of supply, thermocouple terminals supplies as a pair. Every article of thermocouple terminal diversion is made of the difference of metal materials. In view of the different types of thermocouple, discriminating response terminals. Conductive materials should be used in the thermocouple in the terminal with a thermocouple full differences of conductive materials, to ensure that the thermocouple with accuracy in reporting process. Industrial thermocouple removal as a measurement of the temperature transmitter with performance instrumentation, daily record meter with electronic control device matching application. It can directly measure the produce process from 0 ℃ to 1800 ℃ in the category of liquid, vapour and gas medium and temperature in the name of the solid.

according to the country, our company produce accord with IEC international scale index number of platinum rhodium 30-6 10 - platinum and platinum rhodium platinum rhodium, nickel chrome - nickel, nickel chromium - constantan remove the thermocouple, and so on.

by the temperature sensing element, remove the thermocouple weekdays device firmly installed with junction box, and other important components.

可选型号

B型、S型、K型、E型

重要技巧参数

丈量范畴及根本偏差限

热电偶种别

代号

分度号

丈量范畴

根本偏差限

镍铬-康铜

WRK

E

0-800℃

±0. 75% t

镍铬-镍硅

wrn

k

0 - 1300℃

±0。 75% t

13 - platinum rhodium 铂

方面

r

0 - 1600℃

±0. 25% t

铂铑10 -铂

wrp

s

0 - 1600℃

±0。 25%t

铂铑30-铂铑6

WRR

B

0-1800℃

±0. 25% t

calibration with bipolar comparison method, the standard of high grade platinum rhodium platinum thermocouple with K type thermocouple put charging, when heated to a certain temperature, measuring the potential MV values, and platinum rhodium platinum thermocouple again the value of the comparison, by calculating the K type I qualify.

K type thermocouple is a kind of temperature sensor, K type thermocouple and display instrument, usually record instrument and electronic regulator.

the above is the whole of the k type thermocouple method of use, hope useful for everyone

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect