Liquid level meter, — Magnetic flap the installation instructions of the thermometer

KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

for top mounted magnetic flap thermometer and side mounted magnetic flap thermometer, should pay attention to the accuracy of the level measurement, in safety and convenient maintenance to give positive consideration to, and can not affect the normal operation and safety production equipment operation. To meet the demand of some of the above. Selecting for magnetic flap thermometer and accessories to consider when installation, with reference to the above requirements, should pay attention to the following: KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

top with magnetic flap thermometer installation instructions: KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

1, the top dress magnetic flap thermometer is generally installed in the ground tank, installed is not conducive to the side and side will affect the use of special requirements, such as top of magnetic flap is generally selected thermometer. Hole on the top of the roof when must pay attention to the size, the smallest hole cannot be less than 55 mm, the size of the hole, the greater the for the blind spot of the thermometer is less, the size of the flange should be greater than DN40 flange, when installation should keep the vertical of the thermometer, others didn't. KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

side mounted magnetic flap thermometer installation instructions: KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

2, side mounted magnetic flap thermometer is mounted on the side of the tank, to pay attention to the vertical upper and lower flange, and guarantee the flange surface parallel, at the time of installation magnetic flap thermometer, best equipped with ball valve or stop valve, easy in maintenance, cleaning, change does not affect production. Don't need to shut down and then magnetic flap for the repair of the thermometer. KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

notes: when install remote transmitter KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

3, remote transmitter is bound on the magnetic flap thermometer, when installation should pay attention to the transducer zero point with magnetic flap thermometer under the alignment, liquid inlet to reach full time and on the alignment of liquid port, and then in the test, in case of the flap when reading error is bigger, twitch remote transmitter, as to achieve the precise location of the remote transmission of data. KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

notice: when you install alarm switch KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

4, the choice of the alarm switch, the liquid level need to call the police, the need to control, the need to install the alarm switch, if there is a remote transmitter, can also be controlled by digital display instrument, alarm control. If not, you need to install the alarm switch, alarm switch installation position is need magnetic flap, the position of the thermometer, bundled alarm switch, alarm switch line up according to their needs well. Magnetic flap KGV | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

5, magnetic flap, the special way of installation of the thermometer, requires the manufacturer to customize, then in accordance with the manufacturer for installation and debugging. KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

KGV magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

recommended reading: magnetic flap thermometer easy appear what problem? Magnetic flap | | glass thermometer thermometer KGV floating ball | | glass thermometer thermometer two-color thermometer

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect