Expert Thermocouple & RTD &Temperature Sensor Manufacturer.
Micro-armoured thermocouples have many advantages such as flexibility, high pressure resistance, fast thermal response time and durability.
The micro-armoured thermocouple is the same as the industrial assembled thermocouple. It is used as a transmitter for measuring temperature. It is usually used with display instruments, recording instruments and electronic regulators. It can also be used as a temperature sensing element for assembled thermocouples. It can directly measure the temperature of liquid, steam and gaseous media and solid surfaces in the range of 0~800℃ during the production process of famous species. It is suitable for temperature measurement and control in narrow and curved places. It is an indispensable temperature measurement device in the chemical, chemical fiber, pharmaceutical and other industries.
working principle
◇The two ends of the conductors with different components are welded to form a loop. The direct temperature measurement end is called the working end, and the wiring terminal end is called the cold end, also called the reference end. When there is a temperature difference between the working end and the reference end, thermal current will be generated in the loop. Connect the display instrument, and the instrument will indicate the corresponding temperature value of the thermoelectromotive force generated by the thermocouple.
◇The thermoelectromotive force of the armored thermocouple will increase with the increase of the temperature of the measuring terminal. The thermoelectromotive force is only related to the thermocouple conductor material and the temperature difference between the two ends, and has nothing to do with the length and diameter of the thermoelectrode.
◇The structural principle of the armored thermocouple is that it is made of a conductor, a high-insulation magnesium oxide, and a 1Cr18Ni9Ti stainless steel protective tube with a jacket, which is drawn as one piece. Armored thermocouple products are mainly composed of junction box, terminal block and armored thermocouple, and are equipped with various installation fixtures.
◇There are two types of armored thermocouples: insulated type and shell type.
The main technical parameters
◇Accuracy grade: Class I or Class II
◇Nominal diameter: Φ1.0, Φ0.5
◇Bending diameter: R≥5D
◇Nominal pressure: normal pressure
◇Thermal response time of armored thermocouple: When there is a step change in temperature, the time that the output of the thermocouple changes to 50% of the step change is called thermal response
Response time, expressed by τ0.5.
◇Insulation resistance: When the surrounding air temperature is 20±1.5℃ and the relative humidity is not more than 80%, the insulation resistance value between the couple wire of the insulated armored thermocouple and the outer tube should meet the requirements of the following table.
◇Flexibility: The flexibility radius of the armored thermocouple is not less than 5 times its outer diameter.
◇The outer diameter of the armored thermocouple is d≤¢5mm, and there are products with splash-proof or waterproof junction box. Please note that when installing the thermocouple, the exposed part of the device must be equipped with auxiliary supports such as brackets to increase rigidity and ensure firmness , To prevent the junction box from shaking back and forth and damaging the thermocouple.
Installation fixed form
◇The fixing device is for users to install. In addition to products without fixing devices, the armored thermocouple fixing devices have four structural forms: fixed ferrule type, movable ferrule type, fixed flange, and movable flange. The fixed card sleeve type can be fixed at one time by the user, and the movable card sleeve type can be fixed multiple times.
Armoured thermocouple free end (junction box) form
◇The junction box is used to connect the free end of the thermocouple and the display instrument. At present, there are simple, splash-proof, waterproof, handle, small junction box, and compensation conductor types.
◇With compensation wire
◇Splash-proof
◇Waterproof
◇Handle type
◇Small junction box type
The micro-armoured thermocouple has many advantages such as flexibility, high pressure resistance, fast thermal response time and durability. It is the same as the industrial assembled thermocouple. As a transmitter for measuring temperature, it is usually combined with display instruments, recording instruments and electronics. The regulator is used in conjunction with it, and can also be used as a temperature sensing element for assembled thermocouples. It can directly measure the temperature of liquid, steam and gaseous media and solid surfaces in the range of 0~1000℃ during the production process. It is suitable for temperature measurement and control in narrow and curved places. It is an indispensable temperature measurement device in the chemical fiber, pharmaceutical and other industries
working principle:
◇The two ends of the conductors with different components are welded to form a loop. The direct temperature measurement end is called the working end, and the wiring terminal end is called the cold end, also called the reference end. When there is a temperature difference between the working end and the reference end, thermal current will be generated in the loop. Connect the display instrument, and the instrument will indicate the corresponding temperature value of the thermoelectromotive force generated by the thermocouple.
◇The thermoelectromotive force of the armored thermocouple will increase with the increase of the temperature of the measuring terminal. The thermoelectromotive force is only related to the thermocouple conductor material and the temperature difference between the two ends, and has nothing to do with the length and diameter of the thermoelectrode.
◇The structural principle of the armored thermocouple is that it is made of a conductor, a high-insulation magnesium oxide, and a 1Cr18Ni9Ti stainless steel protective tube with a jacket, which is drawn as one piece. Armored thermocouple products are mainly composed of junction box, terminal block and armored thermocouple, and are equipped with various installation fixtures.
◇There are two types of armored thermocouples: insulated type and shell type.
The main technical parameters
◇Accuracy grade: Class I or Class II
◇Nominal diameter: Φ1 Φ1.5 Φ3 Φ4 Φ5 Φ6
◇Bending diameter: R≥5D
◇Nominal pressure: normal pressure
◇Thermal response time of armored thermocouple: When there is a step change in temperature, the time that the output of the thermocouple changes to 50% of the step change is called the thermal response time, which is represented by τ0.5.
◇Insulation resistance: When the surrounding air temperature is 20±1.5℃ and the relative humidity is not more than 80%, the insulation resistance value between the couple wire and the outer tube of the insulated armored thermocouple should meet the requirements of the following table.
◇Flexibility: The flexibility radius of the armored thermocouple is not less than 5 times its outer diameter.
◇The outer diameter of the armored thermocouple is d≤¢5mm, and there are products with splash-proof or waterproof junction box. Please note that when installing the thermocouple, the exposed part of the device must be equipped with auxiliary supports such as brackets to increase rigidity and ensure firmness , To prevent the junction box from shaking back and forth and damaging the thermocouple.
CONTACT DETAILS
Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
CONTACT US FOR FREE SAMPLE !