loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

NTC thermistor measuring method1

NTC thermistor is a common type of thermistor, has a certain application in multiple areas. When we were in the use of NTC thermistor for NTC thermistor measurement methods are all need to know, this project is to introduce specific NTC thermistor for everybody simple measuring method, hope you can help to you.

a, purpose:

there is no special NTC thermistor test instruments, meters and measuring fixture, but need the NTC thermistor measurements, this method provides a simple test method, reach the precision of the professional level, but can be roughly thermistor resistance and precision measurement.

2, measuring tools and materials:

1, the four and a half multimeter: two pieces.

2, test fixture, a.

3, + / - 01 ℃ temperature measuring instrument: a.

4, stainless steel alligator clip: a couple.

3, measurement methods and steps:

1, first of all, a room with air conditioning temperature control in ℃ to 25 ℃ + 01.

2, place the thermometer in the room, monitoring the indoor temperature.

3, will be a pair of alligator clip exchange on a multimeter pen test respectively.

4, will be a standard thermistor two pins on the alligator clip, multimeter pen at the other end inserted into the multimeter, open the multimeter to dial to the resistance measurement appropriate gears, the multimeter shows that the resistance of thermistor at room temperature. ( Note: the nominal resistance accuracy within + / - 01%, B value accuracy of + / - 1%)

5, the alligator clip placed near the thermometer, the multimeter is used to monitor indoor temperature changes.

6, when the monitoring value is relatively stable at room temperature the multimeter that room temperature is stable, at this time to test the resistance of the indoor temperature, such as alligator clip used to monitor the thermistor resistance and on the accuracy and precision of resistance of the thermistor under test phase at the same time, you can compare measurements.

7, thermistor under test according to the standard of testing at room temperature resistance value plus or minus 5% of judging whether the qualified products.

4, note:

1, 25 ℃ indoor temperature should be controlled within + / - 1 ℃. ( When measuring the must close the Windows and doors, reduce air flow, avoid indoor personnel in and out and walking around) 。

2, when the temperature reach control precision, can be used the same resistance precision comparing thermistor for room temperature monitoring resistance measurement.

3, two pieces of multimeter should check before measuring accuracy, consistency checking for at least two tables.

4, thermistor temperature at room temperature under test shall not be less than 30 minutes, such as the product under test after electricity use, please place the test again after 12 hours.

5, thermometer, monitoring with thermistor, resistor should be placed in the same place indoors, under test so as to ensure the accuracy of the measurement.

6, test, thermal resistance, thermal resistance in the operator's hand, as far as possible to keep a certain distance, to avoid the body's temperature measurement error.

more high-quality sensors at https://www. rtdcn。 Com /

key words: thermal resistance, thermocouple, thermal resistance, platinum resistance, PT100, PT1000, pressure sensor and digital temperature sensor

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect