the pervious to light glass thermometer is a precision instrument, the transportation, handling, must handle with care when unpacking and installation, must not impact, knock, prevent the glass broken. Pervious to light glass thermometer and valve are equipped with a connecting flange, and the measured container together, constitute connectors, as to pick up on the glass tube according to the height of the containers within the medium level. 1 i2 magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
pervious to light glass thermometer use notice: 1 i2 magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
when using, should slowly open the valve into the liquid, glass tube preheating 20 ~ 30 minutes, after a certain temperature, can all open on both ends of the valve into the water or other medium. In use process requirements often drainage, avoid fouling corrosion blocking channels, appear false water level phenomenon. Users shall not remove the glass tube. Thermometer on the fluctuation of the valve flange to the container, the out pipe after installation of flange connection good, slowly open the valve, first to flush lining liquid. For high temperature liquid in the container, should will rear glass tube preheated half an hour in advance can be put into operation, to avoid glass tube suddenly collapsed under high temperature.
1 i2 magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
special note: after long-term use of thermometer, irrigation drainage, should be carried out on a regular basis can be shut off valves up and down, and then open the drain valve will be closed after liquid emptying, micro again open the valve for liquid filling the table after closing, in the end, valve slightly open, open the drain valve, net again and again.
1 i2 magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
1 i2 magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
recommended reading: magnetic flap cover glass thermometer thermometer for 1 i2 magnetic flap | | glass thermometer thermometer floating ball thermometer | | double color glass thermometer thermometer
CONTACT DETAILS
Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
CONTACT US FOR FREE SAMPLE !
For more products related question ,Welcome to inquiry us .