Pressure type thermometer, is based on the sealing temperature measuring system of liquid evaporation changes in the relationship between saturated vapor pressure and temperature, the thermometer for temperature measurement. Pressure type thermometer can remote reading, shockproof requirements. Pressure type thermometer is currently the most widely use scope, performance is one of the most comprehensive mechanical thermometer table. Pressure type thermometer vertical installation. Pressure type thermometer should be installed vertically in no vibration plate; Installation, capillary should be straight, every not greater than the distance of 300 mm head fixed tied up with. Can't bend fold during installation. Capillary cannot bear extrusion pressure type thermometer, and pay attention to keep the capillary clear, can't fold bending. Insert temperature dip insert insert the temperature will warm dip all of the measured medium, and reach the maximum depth as much as possible, avoid the error caused by inserting depth is not enough. Level measurement. Pressure type thermometer use notice: when use should pay attention to clean up and check, regularly test the measured values.