Regarding the noise treatment of air-conditioning ducts

In the actual installation project, the following methods are used for the air distribution pipe. Since the sound can be directly transmitted to the room, there is a certain amount of noise. The following discusses the noise treatment methods of several air distribution pipes: 1. Ceiling return air In order to reduce the noise of the air duct machine, under certain conditions, ceiling return air can be used. Disadvantages: The indoor unit returns the wind in the ceiling, which is equivalent to air-conditioning the entire ceiling. For the room, it reduces the cooling capacity of a small section. Therefore, when the ceiling returns to the air, the ceiling space is as small as possible. Advantages: (1) Material saving (no return air duct, etc.), simple and quick installation; (2) Sound waves are reflected and absorbed in the ceiling after coming out of the air inlet of the internal machine, and the noise at the return air outlet is reduced. Requirements: (1) Prerequisite for ceiling return air: The entire ceiling space, except for the return air outlet, should be separated from other rooms, bathrooms and corridors by a wall, tightly airtight, and the indoor unit must draw in the air from the room. . (2) Sufficient return air space must be left between the indoor unit and the partition wall, and between the indoor unit and the ceiling. The surface of the partition wall facing the air inlet of the duct machine (and the floor around the air inlet in the ceiling, the ceiling) can be pasted with a layer of sound-absorbing material with a thickness of 10-20mm, which can further absorb and reduce noise. When the ceiling returns air, the louver return air vent can be separated from the air inlet of the indoor unit to reduce noise. For example, when the indoor unit is located in the middle of the ceiling, the return air vent can be opened on both sides (or one side) of the ceiling. When the owner requests to reduce the opening of the ceiling, the inspection port and the return air vent can be applied. There are two treatment methods: (1) Install an openable return air vent of not less than 450X450 at the ceiling on the inspection side of the indoor unit. (2) Taking into account the needs of motor inspection, a longer return air outlet can be set under the motor (at the same time it can be inspected to the motor, electrical box, and refrigerant departments), which also serves as an inspection port. 2. Dust pipes before and after the air duct machine, and set the air duct elbow. The dust pipe before and after the air duct machine, and the installation of the air duct elbow under the prerequisite conditions is a good way to reduce noise. The noise is refracted and absorbed when it passes through the elbow. , There will be a significant attenuation. It is recommended to use the centrifugal glass wool composite air duct with sound absorption function with the inner wall of the glass cloth coated surface for the air distribution duct, which has a good noise reduction effect.

Wow, this sounds like a bit of a cruel question, but it is a vitally important question to ask yourself if you are struggling with your RTD supplier and you would like to stop the resistance temperature detector problem.

To find an ideal of your need, please visit my site Jiutian Temperature Products.

Utilizing high technology to manufacture products can afford a fully experience to customers by using temperature sensor.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.