loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

S type thermocouple and the advantages and disadvantages between k type thermocouple and the performance parameters of the contrast

S type thermocouple and k type thermocouple is already very common in our work life, everybody has what cognition for the two thermocouple, in fact, if we don't ponder their performance characteristics, also can't distinguish what is good and k s type thermocouple type thermocouple and perfect. Below we three chang to distinguish the advantages and disadvantages of the two thermocouples.

k type thermocouple

k type thermocouple advantages:

1, high temperature metal thermocouple cheap, cheap, widely used, the annual production of nearly half of all metal thermocouple;

2, good reproducibility, approximate linear relationship between thermoelectric potential and temperature;

3, thermoelectric potential: 52. 4 mv / 1300 ℃, high rate of thermoelectric potential: 41 uv / ℃;

4, good oxidation resistance can be used in oxidizing atmosphere and air medium and long term;

s type thermocouple advantages:

s type thermocouple

1, high measurement precision, s type thermocouple of all the thermocouple measurement precision is very high;

2, physical and chemical performance is stable, good reproducibility.

3, good oxidation resistance at high temperature.

2, two kinds of thermocouple faults

k type thermocouple:

1, the stability is a bit poor, in the 150 - Magnetic change very easily within 200 ℃, 250 - 550 ℃ range, can appear the thermoelectric potential and heating process specification change not ( Back to the poor inconsistent) , if used at high temperature for a long time, the thermoelectric performance is unstable;

2, doesn't fit in a vacuum, using carbon, sulfur atmosphere;

s type thermocouple drawback:

1, the precious metal thermocouple, the cost is high, all the thermocouple series, only slightly lower than b type thermocouple price;

2, poor mechanical strength, small thermoelectric potential, especially in low temperature, thermocouple is small, need measuring instrument with high sensitivity;

3, hot wire electrode diameter ( 0. 35mm- 0. 5毫米) Very fine, poor mechanical strength;

the basic principle of thermocouple temperature measurement are two different components of the material of conductor closed loop, when temperature gradient is at both ends, the loop will have an electric current passes through, the existed between both ends of electromotive force & ndash; — Thermoelectric emf, this is the so-called seebeck effect. Two different components of homogeneous conductor electrode as heat, the temperature is higher for work at the end of the end, one end of the low temperature as the free end, usually free end under a constant temperature. According to the thermoelectric emf as a function of temperature, the thermocouple indexing table; Indexing table is free end temperature at 0 ℃, under the condition of different thermocouples with different indexing table.

in the thermocouple circuit connected to the third kind of metal material, the two contacts at the same temperature as long as the material, produced by the thermocouple thermoelectric is set to remain the same, which is not affected by the third metal access in the loop. Therefore, when the thermocouple temperature measurement, can be connected to the measuring instrument, measured after the thermoelectric emfs, can know the temperature of the measured medium. Thermocouple measuring temperature to the cold end ( Measure the end for the hot end, by the end of the lead connected to the measurement circuit is called cold junction) Temperature remains constant, the size of thermoelectric potential and measured temperature in certain proportion relationship. When measuring, the cold end ( Environment) Temperature changes, will seriously affect the accuracy of measurement. Take action at the cold end compensation due to the impact of the cold end temperature change is called the thermocouple cold junction compensation is normal. Connected to the measuring instrument with special compensation conductor.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.