the failure phenomenon: there is a magnetic flap thermometer, normal should be is a place where there is water should be red, no water should be white, what has happened is that no matter how the water level change, at the interface between water and gas is red, the other with water and without water part is white, it should be how to adjust excuse me? Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

failure analysis: Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

1, the verification process to verify level real value, confirmed that really have the liquid level. Or open diversion check whether really have the liquid level. Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

2, check whether the cut-off valve open. If there is a float liquid level inspection, confirm the switch valve, back into the magnetic flap thermometer. Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

the solution: Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

because of using temperature time, liquid level, float in what position. Since at the interface between water and air are red, said there was no jam float, it is well done, under the water vapor interface directly to the frame with magnet to turn into red. If putting-in-service proactively thermometer again to reduce the level to zero. Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

with the iron on the wall, and confirm the position of the float, confirm the float have no card, then float the part painted red, above is white, if you still don't trust, can discharge first, emissions and putting-in-service proactively again. Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

are usually rotor card, to see if the display is damaged, the foreign body. If not, float CARDS, demagnetization problem has said has been very fine. Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

welcome to browse the magnetic flap thermometer technical articles, the author of this thermometer factory automation instrument co. , LTD in jiangsu, indicate the source Nul reprinted magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

Nul magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

click return to homepage Nul magnetic flap thermometer thermometer factory | | glass thermometer floating ball thermometer | | double color glass thermometer thermometer

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect