Specific reasons caused thermocouple thermal response time is too long

Thermocouple, relatively cheap and high precision, and its relatively wide measuring range, so are widely used in many industries. But as in use process, interference by external factors, the performance and measuring will produce certain effect, such as response time.

in addition to the influence of external factors, thermocouple in the process of unceasing development, in order to adapt to different environment, the use of the type of thermocouple is not short in growth, and according to the American national standards institute ( ANSI) Convention, the larger letters indicate its composition. J type thermocouple, for example, by a metal conductor and a copper nickel alloy conductors. Thermocouple other types including B, E, K type thermocouple, N, R, S, and T. The following give you specific introduction of thermocouple thermal response time is too long.

the three major factors influencing the thermocouple response time:

a, the response time of the thermocouple and its structure and size. The hot electrode, protecting tube diameter is more coarse and wall more thick, then its inertia, the greater the making the interval of reaching stability state of thermocouple is longer, will also affect its response time.

2, thermocouple response time also along with the change of working condition is different, that is to say the same of the structure of the thermocouple, under the condition of different heat exchange, the response time is different.

3, the production of thermoelectric materials, heat conduction performance is also different. Such as metal protection tube compared with ceramic protection tube, the heat conduction performance is good, so the thermal inertia is small, and the interval of reaching stability state of thermocouple is short, short response time.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect