Expert Thermocouple & RTD &Temperature Sensor Manufacturer.
Pressure type thermometer is the use of heat pump type system of measuring temperature instrument. So-called heat pump type system, by inductive charging temperature, medium temperature, capillary and pressure sensitive elastic element consisting of all metal components. It is according to in closed containers of liquid, gas or low boiling point liquid saturated steam heated volume expansion and pressure change this principle and production, and pressure gauge to measure the pressure change. When the temperature changes, the temperature of working medium pressure changes caused by expansion, the pressure changes in the capillary to the elastic element ( Such as spring tube) , make the deformation of elastic element, the transmission mechanism make the pointer along the scale deflection, indicates the corresponding temperature value, thus the measured temperature. As capillary pressure type thermometer can be up to dozens of meters, and has simple structure, low price, is widely used in the production process of the distance of corrosive liquid or gas temperature measurement. We often use is circular gauge steam, gas, pressure type thermometer. Steam pressure type thermometer and the primary difference between gas pressure type thermometer
influence factors of steam pressure type thermometer
gas pressure type thermometer
heat medium scale divisions for the nonlinear relationship between the pressure and temperature, so the scale is not equal
turn plexus medium for the linear relationship between the pressure and temperature of bisected so scale
bulb size bulb smaller packages larger
temperature
use range does not exceed 200 ℃ can achieve 500 ℃ 600 ℃
the environment temperature to do not produce additional error value for the
to influence value, compensation measures should be taken to
the atmospheric pressure to generate additional value for error and need correction before use the
impact on basic no value for the
installation position header and the location of the bulb to have additional value for error, one should be in the same height as far as possible
header and the impact of bulb location can be ignored