loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

The control and display functions of the welding air duct fire control equipment for the smoke prevention and smoke exhaust facilities are not perfect

According to the requirements of Article 6.3.9 in the standard GB50116-98: after the fire alarm system is determined, the air-conditioning supply at the relevant position of the galvanized air duct must be terminated, the electric fire damper should be turned off, and the feedback data signal should be accepted; The smoke prevention and exhaust system, fire smoke exhaust fan, smoke exhaust fire damper, etc. at the location, and accept their feedback data signals. In some engineering projects, it is not possible to systematically operate the smoke exhaust and fire dampers and air supply outlets in a system-by-zone manner, and some cannot accept their feedback data signals, and cannot reflect the opening and closing of various valves. Galvanized air duct specification pipeline network gas fire extinguishing system software without pneumatic smoke exhaust fire damper. Article 6.3.4.3 of GB50116-98 stipulates: 'In the period of the court, fire doors, windows and windows should be automatically closed, the ventilation and air conditioning engineering system software should be terminated, and the smoke exhaust and fire dampers at the relevant positions should be closed.' This stipulates that in the pipeline In the software of the gas fire extinguishing system, a pneumatic smoke exhaust fire damper must be installed to be linked with the fire safety control system. There is no role in some engineering projects. There is no remote operation of galvanized air duct equipment when the exhaust and smoke exhaust systems share air ducts. Some engineering buildings, villa basements and underground parking lots use the same air ducts as the exhaust and smoke exhaust systems. The cut-off valve in front of the smoke system machine is only manually operated on the spot, and the remote operation of the main control room cannot be completed. Usually, when the ventilator is working, the cut-off valve developed at the front end is open. In the event of a fire, someone needs to go to the spot to close it The shut-off valve in front of the centrifugal fan, which is very unspecific, immediately endangers the smoke prevention and exhaust system. Therefore, its shut-off valve is proposed to enhance the remote operation effect. System software linkage adjustment and maintenance management method Fire control valve and smoke exhaust fire damper are not a separate product of aluminum silicate fiber for smoke prevention and exhaust system in specific projects, but they are unique in all automatic fire alarm control systems. Different linkage logic sequences. Therefore, in order to ensure its full play in the fire protection facilities, before the acceptance of the system software project, it is necessary to carry out all-round adjustments according to the linkage regulations, so that the natural ventilation, central air conditioning and fire hydrant systems meet the standard requirements. After the acceptance of the project, full-time personnel are required to carry out planned daily maintenance and management methods to ensure that the oil circuit board is in all normal conditions and to give full play to its role in the function of aluminum silicate fiber in the smoke prevention and exhaust system.

If you are looking for convenient, affordable , JVTIA brings plethora of options to suit your requirements and budget both. Check Jiutian Temperature Products for more details.

Hard work and performance is rewarded through bonuses and commissions. Job satisfaction is very important for employees and owners, Shanghai Jiutian Automation Equipment Co., Ltd will create a work environment that is enjoyable and profitable for all.

To stay in contact for latest review of resistance temperature detector RTD supplier across the globe and find out quality products, just go to Jiutian Temperature Products.

Shanghai Jiutian Automation Equipment Co., Ltd has an excellent staffs who will guide you with their best ideas by keeping in constant touch with your company and informing about the market trends.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.