loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

The difference between thermocouple and thermocouple what is the difference between pt100 and cu50 _ instrument2

Thermocouple is one of the industry commonly used temperature detecting element, the working principle of the thermocouple is based on baker ( seeback) Effect, that is, two different components of conductor ends connected into a circuit, such as two different connection end temperature, then to produce the physical phenomenon of thermal current in the circuit. The advantage is; 1) high precision measurement. Because of thermocouple direct contact with the object being measured, not affected by intermediate medium. (2) the measurement range. The commonly used thermocouple from - 50 ~ + 1600 ℃ can renew edge measurement, some special thermocouple with low temperature to - 269℃( Such as gold iron nickel chrome) High, up to + 2800 ℃ ( Such as tungsten - Rhenium) 。 3. Simple structure, easy to use. Thermocouple is usually composed of two different kinds of metal wire, but is not limited by the size and the beginning of, outside has protective casing, which are very convenient. 1. Basic principle of thermocouple temperature measurement will be two different welding material A conductor or semi-conductor A and B to form A closed loop, when the conductor A and B two persistent point temperature difference between 1 and 2, occurs between the electromotive force, and thus form the size of A current in the circuit, this kind of phenomenon called the thermoelectric effect. Thermocouple is in using this effect to work. 2. Thermocouple type and structure formation ( 1) Thermocouple types commonly used thermocouple could be divided into two types: standard thermocouple and non-standard thermocouple. Call standard thermocouple is refers to the standard stipulated by the thermoelectric potential and the relationship between temperature, permissible error, and a unified standard score table of thermocouple, it has with matching display instrument to choose from. Non-standard thermocouple or on the order of magnitude less than the range using standardized thermocouple, generally no unified indexing table, mainly used for the measurement of some special occasions. Standardized thermocouple since January 1, 1988 in our country, the thermocouple and thermocouple were manufactured according to IEC international standard, and the set S, B, E, K, R, J, T seven standardization thermocouple type thermocouple for our country unified design. ( 2) The structure of thermocouple in order to keep the thermocouple is reliable, steady work, the structure of its requirement is as follows: (1) of the two thermocouple hot electrode welding must be strong; (2) two hot electrode should be well insulated between each other, in case of short circuit; (3) compensation conductor should be connected to the free cod of a thermocouple to be convenient and reliable; (4) protect casing thermal electrodes should be able to make sufficient isolation and harmful medium. 3. The thermocouple cold end temperature compensation due to the thermocouple materials are generally more expensive ( Especially when using precious metals) And temperature measuring points are far away the distance to the instrument, in order to save thermocouple materials, reduce cost, usually adopt the compensating conductor (of the cold junction of the thermocouple The free end) Reaches to the relatively stable control indoor temperature and connected to the meter terminals. It must be pointed out that the role of the thermocouple compensation wire only extend thermal electrode, make moves to the control room of the cold junction of the thermocouple meter terminal, it itself does not eliminate the cold end temperature change on the influence of temperature, no compensation. So, still need to take some of the other correction method to compensate of the cold end temperature t0 indicates influence on measuring temperature 0 ℃. Must pay attention to when using thermocouple compensating conductor model match, cannot be wrong polarity, compensation conductor should be connected to the thermocouple temperature should not exceed 100 ℃. Commonly used in low temperature zone thermocouple thermocouple is a kind of temperature detector. Its main characteristic is high accuracy, stable performance. Among them is platinum thermal resistance measurement accuracy is high, it is not only widely used in industrial temperature measurement, and is made into standard benchmark instrument. 1, thermocouple temperature measurement principle and material of thermocouple temperature measurement is based on the metal conductor resistance value increases with the increase of the temperature of the properties for temperature measurement. Thermocouples are mostly made of pure metal materials, the application is a lot of platinum and copper, in addition, now began to use the materials such as nickel, manganese and rhodium thermocouple. 2, thermocouple type 1) Ordinary thermocouples from the thermocouple temperature measurement principle, the measured the change in temperature is directly measured by thermocouple resistance change, therefore, the wires of a thermocouple body such as a variety of wire resistance change will affect temperature measurement. 2) Thermocouple thermocouple is by thermal components ( The resistor body) , wire, insulation materials, stainless steel casing combination solid body, its diameter is commonly phi - 2 Phi is 8 mm, xiaoke reaches 0. 25φmm。 Compared with conventional type thermocouple, it has the following advantages: (1) small volume, no internal air gap, thermal inertia, small measuring hysteresis; (2) good mechanical properties, resistance to vibration and shock. (3) can bend, easy to install (4) long service life. 3) Capillary thermocouple ends thermocouple temperature sensing element resistance wire winding by special processing, close to the face in the thermometer. Compared with general axial thermocouple, it can reflect more correctly and quickly end face of the actual temperature being measured, is suitable for measuring temperature bearing and other parts of the face. 4) Flame-proof thermocouple flame-proof thermocouple through the special structure of the junction box, its shell internal explosive mixed gas by affected by sparks or electric arc explosion limit within the junction box, that wouldn't make production field explosion. Flameproof thermocouple can be used in the Bla B3c level zone with explosion danger place temperature measurement. Pt100: used for thermocouple, thermocouple, temperature meter, temperature transmitter, pressure differential pressure transmitter, hot runner heater, compensation cable, control cable, etc. Cu50: used for thermocouple, thermocouple thermometer, thermocouple checking instrument, thermocouple simulator - Thermocouple simulators, copper thermocouple, thermocouple, etc. Pt100 and cu50 measuring temperature is different, pt100 measurement of high temperature, cu50 measuring the temperature of the low.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect