1. Selection of temperature measurement point The installation position of WRP-130 platinum rhodium thermocouple, that is, the selection of temperature measurement point is important. The location of the temperature measurement point must be typical and representative for the production process, otherwise it will lose the meaning of measurement and control. 2. Insertion depth When the thermocouple is inserted into the measured location, heat flow will be generated along the length of the sensor. When the ambient temperature is low, there will be heat loss. As a result, the temperature of the thermocouple is inconsistent with the temperature of the object to be measured, resulting in temperature measurement errors. In short, the error caused by heat conduction is related to the insertion depth. The insertion depth is related to the material of the protection tube. The metal protection tube should be inserted deeper (approximately 15-20 times the diameter) because of its good thermal conductivity. The ceramic material has good thermal insulation properties and can be inserted shallower (approximately 10-15 times the diameter). For engineering temperature measurement, the insertion depth is also related to whether the measurement object is stationary or flowing. For example, the measurement of the temperature of flowing liquid or high-speed airflow will not be subject to the above restrictions. The insertion depth can be shallower, and the specific value should be determined by experiment. 3. The influence of response time The basic principle of contact temperature measurement is that the temperature measurement element must reach thermal equilibrium with the measured object. Therefore, it is necessary to maintain a certain period of time during temperature measurement to achieve thermal equilibrium between the two. The length of the holding time is related to the thermal response time of the temperature measuring element. The thermal response time mainly depends on the structure of the sensor and the measurement conditions, which vary greatly. For gaseous media, especially stationary gas, it should be kept for at least 30 minutes to reach equilibrium; for liquids, it must be at least 5 minutes.

The , essentially perfected by temperature sensor manufacturers, is one of the first home appliance to be widely distributed.

Energetic, optimistic entrepreneurs often tend to believe that sales growth will take care of everything, that Shanghai Jiutian Automation Equipment Co., Ltd will be able to fund our own growth by generating profits.

We attach a great importance to domestic market and knows the importance factors of manufacturing temperature sensor, such as producing methods, etc.

Shanghai Jiutian Automation Equipment Co., Ltd will do this by managing our business with integrity and the highest ethical standards, while acting in a socially responsible manner with particular emphasis on the well-being of our teammates and the communities we serve.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.