loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

The main parameters of the NTC thermistor

NTC thermistor is a kind of typical sensitive element, has a certain application in multiple industries. The parameters of the NTC thermistor is more, in addition to the nominal value, the basic indicators such as power rating and allowable deviation, and some users have to master the main parameters. Engineering today is for everybody to introduce specific main parameters of NTC thermistor, hope you can help to you.

main parameters of the NTC thermistor:

1) Measuring power: refers to the provisions of the environmental temperature, resistance caused by measuring the power heating resistance changes less than 0. 1% when the consumed power.

2) Material constant: thermistor is reactive thermal sensitivity of indicators. Generally, the greater the value, the higher the sensitivity and the resistivity of the thermistor.

3) Thermistor temperature coefficient of resistance: it means under the condition of zero power, its every 1 ℃ temperature change caused by the relative change of the resistance value.

4) Thermal time constant: refers to the thermal inertia of thermistor. Namely in the condition of reactive power, when the environment temperature mutations, resistance temperature by the difference between the initial value changes to the final temperature of 63. The time needed for 2%.

5) Dissipation factor: refer to the thermistor temperature increase dissipation power by 1 ℃.

6) Switch temperature: refers to the minimum zero power resistance of thermistor resistance when two times the corresponding temperature.

7) The highest working temperature: refers to the thermistor under the condition of the specified standards, long-term continuous work is allowed to take the highest temperature.

8) Nominal voltage: refers to the voltage regulator with thermistor under the regulation of temperature, and the nominal voltage value of the current work.

9) Working current: refers to the voltage regulator with thermistor in the provisions of the current value in the normal working state.

10) Voltage range: refers to the voltage regulator with thermistor in the specified range of environment temperature range value of the voltage stability.

11) Maximum voltage: refers to the provisions of the environmental temperature, the normal work of the thermistor allows continuous when applying the highest voltage value.

12) Insulation resistance: refers to the provisions of the environmental condition, with the resistance of the thermistor resistance value between the insulation shell.

more high quality thermocouple sensor

key words: thermal resistance, thermocouple, thermal resistance, platinum resistance, PT100, PT1000, pressure thermocouple sensor, digital temperature thermocouple sensor

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect