Mealtimes in a school canteen are compressed. A service window may last only thirty or forty minutes, with several hundred people arriving at once, and for the rest of the day the room is close to empty. The air system has to pull the load down inside a very short window, and it has to live with moisture, cooking fumes and a daily wash-down.
Illustrative image: JVTIADUCT fabric duct system in a school canteen dining hall.
The first is the peak. Sized on average load, the room turns stuffy at the busiest point; sized on peak load, it runs cold the rest of the time. The second is moisture and grease. The dining area is separated from the kitchen, but steam and cooking fumes still migrate, and ceiling and diffuser surfaces collect oil film and condensation. The third is cleaning. Floors are washed and tables wiped every day, and a duct that cannot be taken down becomes a hygiene blind spot.
A fibre fabric duct is a lightweight textile air dispersion system suspended from the roof structure or a secondary ceiling. Air is introduced at low velocity over a large surface: the duct wall is permeable, or fitted with engineered outlets along its length, so air leaves the full run of the duct. In a crowded dining hall that means neither a stuffy pocket nor a strong local draught. There are no metal joints or corroding parts inside the duct run, so there are fewer ledges where grease can settle, and the duct is light enough to be designed for removal, so it can be taken down section by section for washing.
JT-H suits general dining areas. JT-P is worth considering for portioning and preparation zones where air quality matters. JT-T, the insulated composite type, is the better choice wherever a temperature difference or condensation risk has to be managed. JT-N, the non-combustible type, covers dense-occupancy school buildings where the fire specification requires it. Fire performance of the duct material can be checked item by item against EN 13501-1, EN 13823, UL 723 and CE documentation. On layout, the run should follow the table aisles and stay clear of the space directly above the serving counter.
Most rework in canteens comes late: the duct competes with ceiling fans, luminaires and sprinkler runs for the same layer of space; an outlet ends up aimed at the serving hatch; no thought was given to removal, so cleaning means erecting scaffolding. Settling these at concept stage is what keeps maintenance simple later.
For a canteen, good air distribution has one simple test: in the busiest half hour, nobody feels stuffy.