1. The installation of fiber fabric bag type air duct system (1) The fiber fabric bag type duct system should be installed after the civil engineering and all other equipment installations have been completed, and the site is clean, especially sand and paint. , Polishing and engineering debris have been removed. It is best to install after the room has been cleaned. During the installation process, ensure that the workers' hands and installation tools are clean. At the same time, please keep all the tools and equipment that will come into contact with the fabric bag-type air duct system clean to ensure that the fiber-fabric bag type air duct system can have a good appearance after installation. (2) The zipper joints of the fiber fabric bag-type air duct system are all at 3 o'clock. (3) Installation of the pipe joints of the steel cable suspension system: the burrs of the metal pipe joints should be covered with corresponding outer covers (the insulation slightly exceeds the edge of the metal duct) to eliminate the sharp corners of the metal joints; the outer diameter of the metal joints It should be slightly smaller than the diameter of the fiber fabric bag-type air duct system, generally 10-30mm; the length of the metal joint is 300mm, which overlaps and connects with the fiber fabric bag-type air duct system; the fabric air duct inlet is sheathed in the iron sheet Use tightening straps to fasten the pipes. (4) The installation elevation of fiber fabric bag type air duct system: The installation elevation of fiber fabric bag type air duct system refers to the distance between the top of the fiber fabric bag type air duct system and the roof of the building (except otherwise, such as the elevation of the bottom of the pipe). In double-row installation, the top of the suspension device (hanging buckle) with a diameter greater than 300mm is below the top of the fiber fabric air duct system pipe. Pay attention to the distance between the suspension device and the top of the fiber fabric bag-type air duct system pipe. 2. The installation steps of the steel rope suspension system of the circular fiber fabric bag-type air duct system (1) Make and install the suspension system bracket and install the steel rope suspension system. When installing, the steel rope suspension system should be tightened and straightened as much as possible. (2) Install the fiber fabric bag type air duct system entrance on the metal joint. (3) Install the fiber fabric bag-type air duct system to the suspension system through the hanging buckle on the fabric pipe. (If it is not connected with a zipper, install the entrance end first) (4) Connect the fiber fabric bag-type air duct system pipes of each part through the zipper. (5) Straighten the system, and fix the end of the fiber fabric air duct system on the suspension system with a steel rope clamp. (6) Adjust the bolts of the flower basket to make the suspension system straight after bearing the weight of the system. (7) Install suspension points at intervals of 8~10m. The suspension point should be in the vertical direction and on the same plane as the suspension system. 3. Installation of aluminum alloy slide rail suspension system for semi-circular fiber fabric bag-type air duct system (1) Aluminum alloy slide rail is used for the suspension of semi-circular fiber fabric bag-type air duct system. Install slide rails on the ceiling on both sides of the fiber fabric air duct system's diameter. From the end, thread the slide rods on both sides of the fiber fabric bag-type air duct system into the slide rail, pull it toward the entrance to the entrance, fix the entrance, and connect the zipper. . (2) According to the diameter and shape of all fiber fabric bag-type air duct systems, Suokes will provide installation drawings, including parameters such as the distance and height of the suspension system. 4. Fiber fabric bag-type air duct system debugging (1) Before commissioning the fabric bag-type air duct system, the system pipes need to be cleaned. Before connecting the fiber fabric air duct system, be sure to clean the iron sheet air duct (the fan can be turned on to blow out some construction waste in the iron sheet air duct) to ensure good sanitary performance of the system and prevent construction dust from clogging the fiber fabric air duct system. (2) During the installation and commissioning, the pressure of the air cabinet is divided into 2 to 3 levels (such as 100Pa, 200Pa) and gradually rises to the working pressure when the air cabinet is turned on, so as to avoid instantaneous high pressure causing damage to the end of the fiber fabric bag-type air duct system. (3) Turn on the fan to inflate the fiber fabric bag-type air duct system. The fiber fabric bag-type air duct system pipes are neatly arranged along the entire suspension system into a straightened state, and no wrinkles and other phenomena are allowed in the middle.

Shanghai Jiutian Automation Equipment Co., Ltd is specialized in sourcing temperature sensor manufacturers resistance temperature detector through its unparalleled worldwide network of supply. Go to Jiutian Temperature Products, you will surely find your ideal at the most favorable price.

With comprehensive knowledge on temperature sensor,why not visit the highly recommended site Jiutian Temperature Products to get a full appreciation of the best ?

You can get more information from Jiutian Temperature Products for on sale. welcome to visit us and send your inquiry!

According to the latest social survey, more than 50 percent of consumers (across all age demographics) follow a brand before purchasing a product. Therefore, JVTIA's content can make or break a customer's decision to conduct business with you.

Shanghai Jiutian Automation Equipment Co., Ltd really created a whole persona around resistance temperature detector’s manufacturing and selling, and it's so innovative that people really respond to it.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.