Expert Thermocouple & RTD &Temperature Sensor Manufacturer.
C7F magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
C7F magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
magnetic flap thermometer USES principle: C7F magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
magnetic flap thermometer can be seen by the force of the float, if the float is sucked in the liquid level switch don't rise along with the liquid level, or increase the buoyancy, either gravity or decrease magnetic attraction between the float and liquid level switch. If increasing buoyancy, float is bound to increase volume, float gravity will increase, but the float within the buoy, increased volume of allowance. Decrease at the centre of gravity may lead to float up, float prone to turn, touch the ground with buoy; After float weight up, may lead to inconsistent with float liquid level float magnet steel center, magnetic flap skew thermometer. And reduce the magnetic attraction between the magnetic switch and float. C7F magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
the use of magnetic flap thermometer scheme: C7F magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
( 1) Reduce the magnetic float, but can lead to turn slowly turning, lag or action. Because the magnetic flap flip is driven by magnetic attraction of float, reduce the magnetic float, also reduces the magnetic attraction, easy to cause abnormal flap motion. Magnetic flap C7F | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
( 2) Reduce the magnetic micro switch. Float with micro switch magnetic attraction also decreases, and float in the process of rising or falling, float to drive smaller, the power of the micro switch magnetic flap thermometer work will not be affected. Magnetic flap C7F | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
( 3) Increasing the float and the distance of the micro switch, because of magnetic attraction is along with the distance of the magnetic materials, and increase with the decrease of the distance will also reduce the float for micro switch magnetic attraction. Concrete can be in in the buoy micro switch with iron, thicken with micro switch again after certain level, make the magnetic attraction to float just can drive the float and the gravity is not too big. Magnetic flap C7F | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
( 4) Increase the rotation Angle micro switch, micro switch in float under the action of magnetic force, can the rotation Angle, but because of the limitation of micro switch is round the actual rotation Angle is small. After increasing the rotation Angle, micro switch magnetic column with float turn up, turn to the limit column, if the float and micro switch magnetic force is small, then the float will not force by micro switch is very big. C7F magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
C7F magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
C7F magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer
recommended reading: installation method can determine the difference of the magnetic turn over the life of the thermometer C7F magnetic flap | | glass thermometer thermometer floating ball thermometer | | double color glass thermometer thermometer
CONTACT DETAILS
Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
CONTACT US FOR FREE SAMPLE !
For more products related question ,Welcome to inquiry us .