loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

The reason of false level traced back inspcetion thermometer

HA3 magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer

two-color thermometer thermometer factory according to customer reflect, according to the principle of analysis it is concluded that the following causes of float magnetic thermometer false level:

1. Because of the other devices to work together, the inspcetion thermometer signal circuit fault.

2。 Because of manufacturer is telephone installation instruction, from operators waveguide installation is not correct, to the internal wire waveguide fault, such as loose, bad sealing water rust, etc. , cause the distortion of signal transmission.

3。 Too much interference signal, circuit is false signal, not the actual measuring signal;

thermometer factory factory tip: also called float inspcetion thermometer thermometer. Structure, on the basis of the principle of by-pass pipe leading tube liquid level and liquid level height consistent within the container equipment, according to the Archimedes theorem, the magnetic float liquid level in the buoyancy and gravity balance, float to float on liquid surface, when the measured liquid level fluctuation of the container, the thermometer float in the main tube also subsequently lifting, float in the permanent magnets by magnetic coupling driving indicator in the red and white double column turn 180 degrees, when the liquid level rises, double column from white to red, the liquid level falls, double column from red to white, indicator of red and white containers within the medium level the actual height of the world and showing the phenomenon of liquid level and inspcetion magnetic thermometer is one of the most widely used thermometer, its operation is simple, use reliable by the favour of people, so about the phenomenon of false level can completely in accordance with the above information. HA3 magnetic flap | | glass thermometer thermometer floating ball | | glass thermometer thermometer two-color thermometer

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect