High-speed rail concourses and metro interchange halls share the same set of constraints. The ceiling is extremely high, passenger numbers rise and fall in tides across the day, and most travellers are walking or standing briefly rather than sitting for hours. Supply air in such a space has to remove the heat generated by people and lighting during the peaks, yet avoid creating draughts or lifting floor dust during the quiet hours. Fabric air ducts, also called textile ducts, address exactly these two conditions.
1. Heat Stratification Under an Extreme Ceiling
Concourse clear heights often reach well over ten metres. In winter, warm air collects against the roof structure; in summer, cooled air settles near the floor. The resulting vertical temperature difference is significant, and a conventional point diffuser loses its jet momentum long before it covers the full section. A fabric duct running continuously along the length of the hall releases air through micro-perforations over a large surface, delivering conditioned air towards the occupied level and reducing the vertical spread.
2. Tidal Passenger Flow and Draught Control
Instantaneous occupancy at the morning and evening peaks can be several times the off-peak figure, so the cooling load swings widely. Fabric ducts discharge air with low momentum and even diffusion, keeping air speed in the occupied zone low enough that travellers do not register a draught. Air volume can be balanced through internal static pressure and allocated by time of day, which avoids over-cooling during the quiet periods.
3. Lightweight Suspension Under Long-Span Roofs
Transit buildings generally use long-span steel roof structures with limited spare load capacity, and the ceiling zone is already crowded with luminaires, conduits and signage. A fabric duct is light in weight and hangs from steel cables or tracks, adding little load to the truss and allowing the routing to follow the roof geometry. Its woven surface is left in its natural colour, which is easier to reconcile with the architectural ceiling than a sheet metal run.
4. Dust Accumulation and Washing in an Open Public Space
Interchange halls are densely occupied and their entrances open constantly, so dust and particulate matter enter with the airflow. Fabric ducts can be taken down section by section and machine washed, and routine maintenance does not require extensive scaffolding. For high-occupancy assembly spaces, the JT-N non-combustible fabric can be specified; the product range meets EN 13501-1, EN 13823 and UL 723 and carries CE marking.