The use of the thermocouple _ instrument

Thermocouple ( 热电偶) Is commonly used in temperature measuring instrument of temperature measuring element, and it is directly measured temperature, and the temperature signals into a thermoelectric emfs, through electrical instrument ( Secondary instrument) Convert the temperature of the measured medium. The appearance of all kinds of thermocouple is often due to the need to vary, but their basic structure is roughly same, usually by the hot electrode, insulation sleeve to protect the main parts such as pipe and connection box, by compensating conductor and digital display table, recording instrument and electronic regulator. When there are two different conductors or semiconductor A and B to form A loop, its both ends are connected, as long as the temperature of the two nodes is different, one end of the temperature T, called end or hot end work, on the other side temperature T0, known as the free end, Also known as the reference side) Or the cold end, the circuit will generate an electromotive force, the direction and size of the electromotive force is related to the conductor material and the temperature of the two contact. This phenomenon is called thermoelectric effect, two kinds of conductor circuit known as the 'thermocouple', composed of the two conductors referred to as the 'hot' electrode, the electromotive force is called 'thermoelectric emfs. Thermoelectric emfs is composed of two parts of electromotive force, part two conductor contact electromotive force, the other part is a single conductor of temperature difference electromotive force. The size of the thermocouple loop thermoelectric emfs, only with the composition of the thermocouple conductor materials related to the temperature of the two contact, and has nothing to do with the shape size of the thermocouple. After the thermocouple fixed two electrode materials, contact temperature t and thermoelectric emfs are two t0. The function of the poor relation has been widely applied in the actual temperature measurement. Because of the cold end t0 constant, produced by the thermocouple thermoelectric emfs only with the hot side ( Measurement end) Temperature changing, that is, a certain amount of thermoelectric emf corresponds to a certain temperature. As long as we use the method of measuring the thermoelectric emfs can achieve the purpose of temperature measurement. Thermocouple temperature measurement is the basic principle of two kinds of different ingredients of closed loop conductor material composition, when when there is a temperature gradient at both ends, loop will have an electric current passes through, the existed between the electromotive force on both ends - Thermoelectric emf, this is the so-called seebeck effect ( 塞贝克效应) 。 Two different components of homogeneous conductor electrode as heat, the temperature is higher for work at the end of the end, one end of the low temperature as the free end, usually free end under a constant temperature. According to the thermoelectric emf as a function of temperature, the thermocouple indexing table; Indexing table is free end temperature at 0 ℃, under the condition of different thermocouples with different indexing table. Access in the thermocouple loop when the third metal material, the two contacts at the same temperature as long as the material, produced by the thermocouple thermoelectric is set to remain the same, which is not affected by the third metal access in the loop. Therefore, when the thermocouple temperature measurement, can be connected to the measuring instrument, measured after the thermoelectric emfs, can know the temperature of the measured medium. Thermocouple measuring temperature to the cold end ( Measure the end for the hot end, by the end of the lead connected to the measurement circuit is called cold junction) Temperature remains constant, the size of thermoelectric potential and measured temperature in certain proportion relationship. When measuring, the cold end ( Environment) Temperature changes, will seriously affect the accuracy of measurement. Take action at the cold end compensation due to the impact of the cold end temperature change is called the thermocouple cold junction compensation is normal. Connected to the measuring instrument with special compensation conductor. Thermocouple, and temperature display and control instrument is a kind of mature technology, product specifications and rich products supply is adequate. Thermocouple usually have installed devices, such as: fixed screw, fixed flange, etc. , inserted into the pipe at site, measured with compensation wires to signal transmission to the special instrument, such as: digital display table, recorder, intelligent control instruments, etc. , satisfy the measurement and control requirements of the production process. Don't need to measure the electromotive force separately at the scene.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect