loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

Thermal installation method of thermal resistance and thermocouple

Installation of thermal resistance and thermocouple, reliable and accurate temperature measurement is a safe care, but it should help facilitate maintenance, and the operation of equipment and production operations will not be affected. In order to meet the above requirements, the installation position and insertion depth of thermocouples and thermal resistances, please pay attention to the following points. One, there must be a reasonable selection of measurement points, sufficient for the measurement of the thermal resistance of the media and the client, and the exchange between nearby valves, elbow thermocouples, and heat trying to avoid thermal installation of electrical equipment or thermal resistance. Thermal resistance and heat transfer and heat loss and thermocouple protection tube to reduce measurement errors, thermocouple and thermal resistance, it must have sufficient depth. Thermocouples measure the temperature of the core pipe fluid, and a common purpose is to measure the center of the inserted pipe (vertical installation or inclined). Must choose fluid pipe diameter measurement, for example, 200 mm, 100 mm thermocouple or thermal resistance insertion depth. Temperature measurement of high temperature fluid, high pressure, high speed (for example, the main steam temperature fracture), the protective tube light to prevent the action of the fluid protective cover and the liquid protective cover to reduce the resistance You can insert the effect of heat set by the thermocouple. It must be no less than 75 mm, the thermocouple protection pipe plug should be shallow, and the main steam pipe should be inserted. The insertion depth of the sheathed thermocouple thermocouple is 100mm standard; the exhaust gas temperature needs to be measured at the exhaust gas temperature, the flue diameter is from 1 meter to 4 meters, the RTD or thermocouple insertion depth is greater than the original insertion depth of 1 meter, You will need to protect the installation and housing or support frame for vertical installation. How to install two thermocouples and thermoelectrics A threaded car seat, in-line measurement of the size of thermocouples and thermal resistance. The two holes of the pipe can be seated according to the diameter of the screw. Thin plate welding thread. The thread is inserted into the table, with a hole well welded, the thread for the pipe and the gauge table. Good four thermocouples or thermal resistance welding thread precession. According to thermocouple, RTD or wiring, this is the wiring diagram of the junction box corresponding to a dial-up connection with the display unit. Please note that the temperature of the junction box and junction box should be measured with the blood vessel wall so as not to exceed the range from 0 to 100 ℃, and the medium will not come into contact. The installation location of the thermal resistance or thermocouple needs to be considered for easy repair and maintenance.

Finding a reliable solution for the resistance temperature detector RTD supplier not only supports operation of the entire system but also enhance the beauty of your workplace.

If you have any issues with your temperature sensor, you will have to call the experts at Jiutian Temperature Products to assist you. Any of your enquiry is warmly welcomed.

resistance temperature detector has its grasp on oversees market also and has a very good repute.

comes in a vast array of styles and temperature sensor manufacturers depending on which RTD supplieris used.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.