Below for everyone to introduce thermocouple compensation wire type and function of the

a compensation conductor, why use?

because when using thermocouple temperature measurement, temperature of the reference junction of the thermocouple must be constant, or the introduction of measurement error in measuring temperature, will be a big variable, will affect the accuracy of the temperature measurement. But, in the field use the thermocouple reference end often near the high temperature heat source, the thermocouple reference end is affected by the heat source cannot be stable, so must be moved to the temperature of the reference junction of the thermocouple is relatively stable places; Compensation conductor with the same metal as the thermocouple materials, or in the specified temperature range ( Generally 0 ~ 100 ℃) The thermoelectric properties ( Heat up the electricity) Same as the adaptor by the thermocouple, and is easy to get cheap base metal materials, can prolong the effect of thermocouple in the temperature measurement or as a thermocouple and instrument ( Such as electronic potentiometer) The connection of the wires. So, thermocouple compensation when use to connect wires. But it does not eliminate the reference junction is not zero, so that in use or the reference should be revised to 0 ℃ temperature.

2, while using compensation conductor must pay attention to the following:

1. Compensating conductor only with matching type of thermocouples, which is said by all kinds of thermocouple and supporting the use of compensation wire, in the specified temperature ( If 0 ~ 100 ℃) Line heating up the electric power must be consistent.

2。 Compensation conductor in connection with thermocouple instruments, two pairs of points to the same temperature, and is the cathode can't wrong. Compensation conductor should be equivalent to a team in a certain temperature ( 0~100℃ ) Within the scope of the thermocouple, so its current and flow to the cathode by the reference from the positive side, so connected to the thermocouple, the positive can thermocouple of the compensating conductor of the anode, cathode were negative of thermocouple. Such as the polarity inside out, not only lose the function of the compensating conductor, it will offset part of the thermocouple thermal power, the instrument of temperature indicating on the low side.

3。 Compensation conductor and the thermocouple connection point temperature shall not exceed the specified temperature range.

4。 Want to choose according to the different requirements of instrument for compensating lead wire diameter. Such as connected to the moving coil meter compensating lead wires can be made with thicker wire diameter, the resistance is smaller, so as not to affect the external resistance meter.

5。 Lines long thermocouple and can be used more shares and coarser compensating lead wires, in order to facilitate installation and installation.

3, compensation conductor should be due to the core alloy material divided into extension model and compensation model of two kinds:

extended type compensation conductor:

have NX ( Nickel chromium silicon - Nickel silicon magnesium) KX ( Nickel chrome 10 - Nickel silicon 3) 交货( Nickel chrome 10 - Copper and nickel 45) ,JX ( Iron - Copper and nickel 45) TX ( Copper - Copper and nickel 45) 。

compensation type compensation conductor:

with SC and RC ( Copper - Copper and nickel 0. 6) KC ( Copper - Copper and nickel 40) 、NC ( Iron - Copper and nickel) And so on.

4, using expanded or compensation model the timing of the compensating conductor:

extended type:

cold junction compensation wires environment greater than 100 degrees or less than zero, in order to measure the accuracy of, only choose expanded compensation wire, but the price is more expensive. Compensation type:

the cheap, but the cold end temperature should be relatively stable.

5, compensation conductor must possess the characteristics of the:

1. Thermoelectric properties stability, good electrical insulating performance, long service life.

2。 Soft, bending performance good, easy to use.

3. Cladding material is stable and reliable, has certain resistant and cold resistant performance.

thermocouple compensation wire knowledge:

the difference between the thermocouple compensation wire kx and kc wire industry status quo

compensation thermocouple products can't be replaced

how to correctly choose the cause of thermocouple compensation wire

the use of the thermocouple compensating conductor

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect