loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

Thermocouple insulation problems _ instrument

First of all, its positive and negative level generally separated, have a plenty of in the ceramic tube is separated again! Thermocouple for temperature measurement accuracy long take a temperature compensation method, is to find a way to ensure the temperature measuring end has been a constant temperature constant, neither let it is affected by temperature environment. Moreover, thermocouple is through two kinds of metal wire electronic flow to test temperature, metal wire winding copper wire must surely have after the happening of the electromagnetic induction phenomenon, so look, to measure the temperature of the numerical error is for sure! Thermocouple of high temperature insulation problem for thermocouple wire insulation protection, relatively low temperature with enameled wire under 200 degrees, and a polymer material 200 degrees, at up to 600 - 800 ℃ have that kind of stainless steel are directly related to the high temperature alloy alive inside the thermocouple as cable material coated, thermocouple integrated structure of direct powder magnesium oxide powder insulation, the metal coating lines smaller diameter can be less than 0. 5mm。 Thermocouple problems of several kinds of solutions to a problem of high temperature insulation, carried out in accordance with the instrument wiring diagram wiring right after electrify, first instrument display instrument of thermocouple indexing number, and then display instrument range limits, and measuring instrument discharge of digital tube display set temperature, the digital tube display on the meter measuring temperature. If digital tube display on the meter is not the temperature of the heating element, which shows the 'OVER', '0000' or '000', etc, that instrument malfunction, input parts should be done the following test: ( 1) The thermocouple from the meter thermocouple input to be removed, then the instrument with any wire thermocouple input terminal short circuit. On the electricity, instrument digital tube display value approximately at room temperature, thermocouple internal connection open circuit, the same type thermocouple should be changed. If still the status of the said above that instrument in the process of transportation, the input end of the instrument is damaged, to change the instrument. ( 2) The above fault instrument of thermocouple down, switch to run next to normal the same degree, access to the instrument of thermocouple, after electrify, the original fault instrument digital tube display on the heating element temperature, thermocouple internal connection open circuit, replace the same type thermocouple. If still the status of the said above that instrument in the process of transportation, the input end of the instrument is damaged, to replace the instrument. ( 3) The defective thermocouple removed from the instrument, measured with a multimeter in ohms ( R) * 1 file, use multimeter thermocouple at both ends, two table stick to test if the multimeter display on resistance value is very big, thermocouple internal connection open circuit, replace the same type thermocouple. Or have a certain value, the instrument input has a problem, should replace the instrument. ( 4) According to the instrument wiring diagram wiring is correct, if the instrument after electrify, digital tube display meter race such as negative phenomenon, illustrate access instrument thermocouple '+' and '- 'Wrong. Just need to change. ( 5) Wiring correct instrument at run time, the temperature of the instrument on the digital tube display and the actual measurement of the temperature difference of 40 degrees to 70 degrees. Even bigger difference, the instrument of indexing, and thermocouple dividing, make a mistake. By thermocouple indexing, B, S, K, E, etc. The temperature of the thermocouple and the millivolt ( MV) The value of the corresponding relation, under the condition of same temperature, the millivolt values ( MV) B the minimum degree, S degree, small, K index number is larger, E index number is larger, discriminant according to this principle.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect