loading

Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

Ultrasonic level meter common problems

1, stirring effect on ultrasonic level meter:

the containers are often stirring, liquid fluctuation is bigger, affect the ultrasonic level meter measuring; This kind of circumstance can properly reduce the speed of agitator, or at the center of the probe from stirring; Also can install the static tube, thus effectively eliminate for blender mixing the impact of the level measurement.

2, bubble effect on ultrasonic level meter:

in ultrasonic level meter to measure the liquid level in the process, often encounter the interference of bubbles. Foam according to the attributes can be divided into: dry, wet, neutral, four kinds of heavy.

dry foam and wet the ultrasonic can be reflected, so can not influence the ultrasonic level meter to measure; Neutral foam will absorb and diffuse part of the ultrasound, which will weaken the ultrasonic reflection, lead to echo instability. So when the surface of the medium to thick and thick foam, ultrasonic liquid level gauge measurement error will be larger, even you can't measure.

in severe working conditions, the FLOWLINE ultrasonic level meter can be equipped with shield static tube to bubble. This is Beijing kang Nathan company exclusive patented technology.

3, steam, the fog effect on ultrasonic level meter:

when working environment temperature is high, the liquid medium is easy to produce steam or fog, because the steam is lighter than air, so to rise to the top, to form a layer of ultrasonic pulse is absorption and scattering of vapor layer. Through adding static tube, can reduce or weaken the steam layer effect on the measurement.

4, blind area of SF - P ultrasonic level meter:

ultrasonic level meter blind area, like people's eyes, blind area when the object is near the eyes is very close, but can't see clearly, this distance is called the blind area.

  SF- P blind area of the ultrasonic liquid level meter, varies according to the range. Small range, the blind area, range is big, the blind area. So the measurement of the highest level shall not be higher than that of the ultrasonic level meter blind area.

5, pressure and temperature on the influence of ultrasonic level meter:

in the first place, the speed of sound can't spread under vacuum, and the essence of the ultrasonic wave is a kind of sound waves, and belongs to the mechanical wave, so it cannot travel through a vacuum.

second, is the temperature, while the parameters of the ultrasonic level meter summary have maximum pressure value, but with the increase of temperature, the maximum pressure value will be reduced accordingly, so attention should be paid to this parameter in the selection.

in addition to the outdoor installation of the liquid level meter, can be used to add sun shade and other measures to weaken the influence of temperature factor.

static tube patent technology installation note: SF - P ultrasonic liquid level meter of Echo - has been adopted Pipe technology, allowing the detector installed in the 2 '4' metal or nonmetal catheter, outside of the tube wall reflection wave interference, suitable for mixing, foam, water vapor and around obstacles generated clutter environment application.

when installing catheter pay attention to the following:

1, select the appropriate pipe diameter.

2, catheter internal smooth, no welding seam.

3, in the blind area in open holes, ensure pipe pressure balance inside and outside.

4, catheter bottom to be submerged under the lowest measuring liquid level.

the bottom 5, 45 ° inclined to open mouth, maintain the normal flow liquid.

more high-quality sensors at https://www. rtdcn。 Com /

key words: thermal resistance, thermocouple, thermal resistance, platinum resistance, PT100, PT1000, pressure sensor and digital temperature sensor

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect