Expert Thermocouple & RTD &Temperature Sensor Manufacturer.
All the instruments in use of the time there is a certain fault, thermal resistance is no exception. Thermal resistance thermometer at the time of measurement error is also will appear the error, so what is the cause of thermal resistance thermometer error? As long as find a reason to quickly solve, the following project is to introduce what is the cause.
( 1) Heat transfer error.
it is due to the side when the temperature is not in contact with the object to be tested fully. Did not reach thermal equilibrium and so on caused by the error, should be in accordance with the relevant specification more careful when using.
( 2) Degree of error.
standardized thermal resistance index table is produced by statistical analysis, adopted by the thermal resistance of concrete, however, because the material, manufacturing process and differ somewhat, this creates a degree error, such as who do not tally with the nominal resistance value and the introduction of error.
( 3) Since the thermal error.
this is due to the measurement of current flows through the heat resistance in the process of falling in to produce the additional error caused. It is related to the current size and heat transfer medium. Industry in our country with the thermal resistance of limiting current is less than 6 ma, so that we can limit the temperature error in 0. Within 1 ℃.
( 4) The error of the measuring circuit and display instrument.
it is by the level of accuracy and display instrument itself line resistance. If use Cu50 type copper resistance temperature measurement, the resistance of the copper wires under prescribed conditions for 50, if measured and remote instrument for 4070 sichuan ℃, environment temperature changes at this time the two wire connection wires can bring about 2 ℃ to measure error, three-wire system connection leads to 0. The error of 1 ℃. In addition, the lead resistance, change the limits of the connection wire in also will cause error.
( 5) Other error.
this is besides the above error. By blocking defective insulation, inserted depth is not enough, such as thermal resistance degradation caused by the error.
more high quality thermocouple sensor
key words: thermal resistance, thermocouple, thermal resistance, platinum resistance, PT100, PT1000, pressure thermocouple sensor, digital temperature thermocouple sensor