Thermocouple in the use of performance on the installation: a lot of problems don't wait for our thermocouple then to solve the problem, can install again when can solve the attention when installation, the use of the relationship between the thermocouple performance.

1. Insert depth. Electric installation the depth of the insert must satisfy the corresponding conditions. Once the actual temperature measurement process, the thermocouple insertion depth is not enough, will be the sidewalls of the protecting tube contact or surrounding environment influence, generating test error. So the insertion depth of the corresponding standard is (1) metal protection tube: 15 - the diameter of the insertion depth of 20 times. (2) the nonmetal protection tube: for a 15 10 times the diameter of the insert depth.

2. The installation direction. Here it is important to note that thermocouple installation position must keep the vertical position, to prevent the protection tube deformation occurs at high temperature. If horizontal temperature measuring element, is affected by high temperature automatic bending, if appear this kind of phenomenon, suggested that the user can choose the refractory or hot metal stents as support, prevention of bending.

3. Installation location. As a kind of temperature measuring device, its installation location is important. General component test M end to measured medium temperature in the correct place. If the test fluid temperature in the pipeline, just couple in the position of the pipeline flow velocity in the biggest work end, at the end of the thermocouple is more than 5 - the center line of the pipeline About 10 mm position.

thermocouple knowledge:

matters that should pay attention to using thermocouple, heat resistance,

thermocouple

of the four basic laws of the working principle of thermal resistance

thermocouple

the causes of measurement errors processing method of the cold junction of the thermocouple

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect