In general, in order to facilitate the monitoring and measuring instrument operation of instrument will be placed on basic constant temperature and facilitate set console, away from the actual temperature measuring point has a certain distance. In the distance, in general situation is more complex, passes through power supply, for example, have electromagnetic interference and so on, and may often be the role of external force. While using thermocouple wire may cause the error of measurement, use is easy to be damaged, often need to change, and so on. And thermocouple wire materials are generally more expensive, if used for long distances, the cost is very high. These, are the reasons why using thermocouple compensating conductor. To sum up, the use of compensating conductor has the following advantages: 1) Improve physical properties and mechanical properties of thermocouple temperature measurement circuit, using multi-strand wire core or small diameter flexible compensation wire line can be improved, convenient wiring, also can adjust circuit resistance or blocking interference; 2) Measuring circuit to reduce costs, distance when the thermocouple and measuring devices, and using the compensating conductor can save a lot of thermocouple material, especially when using the precious metal thermocouple. The classification of the thermocouple compensation wire thermocouple compensation conductor should be divided into two categories: 1) Extended type compensation conductor should be extended type compensation wire is also called extended type wire, the wire in the name of the chemical components and the thermoelectric emfs nominal value and the thermocouple, the same with the letter 'X' attached to the thermocouple said after graduation, such as 'KX' said K type thermocouple with compensation conductor should be extended type. 2) Compensation type compensation conductor type compensation compensation wire, also known as compensation wire, the wire in the name of the chemical composition and thermocouple are different, but the value of thermoelectric emfs, at 0 100 ℃ or 0 200 ℃ with with thermocouple thermoelectric emfs nominal values are the same, with the letter 'C' attached to the thermocouple said after graduation, such as 'KC'. Different wire can be applied to the same degree of thermocouple, and additional letters. 3, how to correctly choose thermocouple compensation wire 1) Compensation conductor index number must be consistent with the thermocouple used, such as K type thermocouple, must use the K type coupling compensation. 2) Choose according to using the environment temperature, low compensation conductor operating temperature range, 0 - general points 100 ℃ and 0 0 to 200 ℃ of two Lower the price of 100 ℃, can choose according to actual need. 3) If the interference sources, can choose anti-jamming strong compensation conductor shielding type. 4) If there are multiple temperature measuring points at the same time, can choose to have multiple sets of compensation wire cable.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.