Expert Thermocouple & RTD &Temperature Sensor Manufacturer.
Abstract: platinum rhodium - 10 Platinum thermocouple ( S type thermocouple) For precious metals thermocouple. Accidentally wire diameter provision of 0. 5 mm, allowable deviation - 0. The positive (015 mm, SP) In the name of the chemical composition of platinum rhodium, contain the rhodium is 10%, platinum-based is 90%, the cathode ( SN) For pure platinum, commonly known as single platinum-rhodium thermocouple. The thermocouple long-term maximum temperature of 1300 ℃, the highest short-term using temperature is 1600 ℃. S type thermocouple in the thermocouple series has the highest accuracy, stability, best to measure your area wide, long service life, etc. Its physical and chemical performance is good, the thermoelectric potential stability and oxidation resistance at high temperature performance is good, suitable for oxidizing and inert atmosphere. Because of S type thermocouple has excellent comprehensive performance, in line with the international use of S type thermocouple temperature scale, has for a long time as an international scale interpolation instruments, 'ITS - Although 90 'provisions will not be as an international scale in check instruments, but the international advisory committee (temperature 有条件现金转移支付) S type thermocouple can still be used for approximate to realize international temperature scale.
product number: 61910423516 product name: WRP - S type thermocouple specifications: 300. 500. 750. Note: 1000 product users have special requirements, can be in the order indicated in the contract. Product categories: thermocouple
product description
10 - platinum rhodium Platinum thermocouple ( S type thermocouple) For precious metals thermocouple. Accidentally wire diameter provision of 0. 5 mm, allowable deviation - 0. The positive (015 mm, SP) In the name of the chemical composition of platinum rhodium, contain the rhodium is 10%, platinum-based is 90%, the cathode ( SN) For pure platinum, commonly known as single platinum-rhodium thermocouple. The thermocouple long-term maximum temperature of 1300 ℃, the highest short-term using temperature is 1600 ℃. S type thermocouple in the thermocouple series has the highest accuracy, stability, best to measure your area wide, long service life, etc. Its physical and chemical performance is good, the thermoelectric potential stability and oxidation resistance at high temperature performance is good, suitable for oxidizing and inert atmosphere. Because of S type thermocouple has excellent comprehensive performance, in line with the international use of S type thermocouple temperature scale, has for a long time as an international scale interpolation instruments, 'ITS - Although 90 'provisions will not be as an international scale in check instruments, but the international advisory committee (temperature 有条件现金转移支付) S type thermocouple can still be used for approximate to realize international temperature scale.
S type thermocouple deficiency is thermoelectric potential, thermoelectric potential rate is small, low sensitive to read, mechanical strength under high temperature to drop, is sensitive to pollution, precious metal materials is expensive, and one-time investment is larger. S type thermocouple is also called single platinum-rhodium thermocouple, its index number is S degree, mainly measuring the temperature of 0 ~ 1600 ℃ medium, is one of the precious metal thermocouple category. Normal use in place of coking plant, steel plant and other high temperature use. S type thermocouple under normal use for a long time at about 800 ~ 1300 ℃ temperature measurement accuracy is the highest, and within 800 ℃ temperature measurement accuracy is not high, but the long-term use of temperature above 1300 ℃ can easily damage the thermocouple, so select the correct index number of thermocouple temperature measurement accuracy is the important factor.
the main technical parameters of electrical exports: M20x1. 5, NPT1/2
accuracy level: I, II
protection grade: IP65
I wire diameter: Φ 0. 5
nominal pressure: the atmospheric types and specifications:
type no.
dividing,
temperature measurement range ℃
protection tube material
thermal response time
gauge,
diameter
length ( L) Inserted deep I
WRP - 130年
WRP2 - 130年
0 - 1600
just the jade high aluminum
< 150 s
Φ 16
300 x150 350 x200
400 x250 450 x300
550 x400 650 x500
900 x750 1150 x1000
1650 x1500 2150 x2000
WRP - 131年
WRP2 - 131年
0 - 1600
< 150 s
Φ 25
the main technical parameters of product standards IEC584 IEC751 JB/T5582 - 1991
the order need to know: 1. Indicate the models, index number, using temperature thermocouple. 2. Thermocouple protection tube diameter, length. 3. Fasteners, flange device, provide the size.
I company specializing in the production of: platinum rhodium thermocouple, K type thermocouple, tungsten-rhenium thermocouples, high temperature thermocouple, heat resistance, KC compensation wire, heating wire, electric stove wire, temperature instrument