WSS - The main factor causing error 411 double metal thermometer

WSS - 411 bimetallic thermometer when measuring temperature, the built-in bimetallic strip are produced according to the temperature as high as the corresponding change, bending degree of bimetallic strip is mainly come from the measured temperature. Will usually small expansion coefficient of bimetallic strip layer called the passive layer, called the first floor of a large expansion coefficient of active layer. As a major cause of bimetallic thermometer appear error what? The following look at together. 1, the environmental conditions: WSS - The bimetallic thermometer should be in temperature is 411 - 40℃本; + 55 ℃, relative humidity is not more than 85% under the conditions of use, otherwise it will cause greater error. 2, mechanical damage, in use, the instrument has been heavily impact and collision, easy to cause the protection tube deformation, thus affecting the normal work caused by the error of measuring mechanism. 3, the fatigue damage: after using for a long time, can make the performance of the sensing element change caused by the error. 4, inserted into the medium depth: WSS - 411 the depth of the bimetallic thermometer inserted into the medium must ensure that is greater than the length of the sensing element, if the insertion depth will cause the error.

GET IN TOUCH WITH Us
recommended articles
NEWS
At present, more and more customers on the market are just beginning to attach great importance to the hidden dangers of the application of air disc machines and equipment.
Ventilation duct manufacturers talk about three welding methods for fabric ducts: Method 1: Manual welding.
It should be erected by the scaffolder according to the special safety construction organization design (construction plan) or safety technical measures.
Compliance Standards and Common Problems in Ventilation Duct Equipment Many bosses generally ignore the smoke exhaust system and natural ventilation planning of the restaurant kitchen when they open a new restaurant, which eventually leads to the closure of the hotel for renovation, renovation or sale of serious losses.
Ventilation pipe ventilation pipe manufacturer is a hollow pipe used for ventilation.
When we want to enter an industry and decide to dedicate our light and heat, our calm choice is to analyze this market well.
How to ensure the construction quality of dust removal fabric duct ventilation duct? In order to promote the construction of dust-removing fabric duct ventilation ducts, we should formulate some drastic measures.
How does the ventilation duct manufacturer ensure the construction quality of the ventilation duct for the dust removal fabric duct? 1.
There are common pipes everywhere in daily life, and it is not clear what to do.
Ventilation ducts are metal or composite ducts for ventilation in industrial and civil buildings.
no data

CONTACT DETAILS

Phone: +86 13816377866
Email: jimmy011@126.com
Add:NO999, Sunqiao RD, Pudong area, Shanghai, China
 

CONTACT US FOR FREE SAMPLE !

For more products related question ,Welcome to inquiry us .

Copyright © 2019 Shanghai Jiutian Automation Equipment Co., Ltd. | Sitemap
Customer service
detect