Expert Thermocouple & RTD &Temperature Sensor Manufacturer.

+86 13816377866    |    jimmy011@126.com

Temperature Controller
Home  > PRODUCT  > Temperature Controller  > 

XMT 7100 Temperature Controller PID

这里可以自定义设置
XMT 7100 Temperature Controller PID
B站不支持收货地址
B站不支持库存规格
参数暂无数据
多属性暂无数据
B站不支持优惠卷

Add success, do you want to check your shopping cart?

暂无分享
B站不支持产品保障
Overview
Quick Details
Place of Origin:
Shanghai, China
Brand Name:
Feilong
Model Number:
XMT-7100
Usage:
Industrial
Theory:
Temperature Controller
Accuracy:
0.1%
Temperature range:
-9999-9999C
Precision:
0.25%FS ± 0.1
Size:
48*24*75(mm)
Power supply:
24V DC
Delivery Detail:
temperature controller
Resolution:
0.1°C for K, E, T, N, J, Cu50, Pt100
Approval:
CE/ ISO9100
Control method:
ON/OFF, PID
Response time:
less than 0.5s
Supply Ability
Supply Ability:
10000 Unit/Units per Week
 

XMT 7100 Thermostat 110v Temperature Controller PID

 

Product Description
modelXMT-7100
typetemperature controller
temperature range -9999-9999C
size 48*24*75(mm)
Power supply 24V DC
graduation B/S/K/N/E/J/T
material PP
certificateCE/ISO9001

Product Images Show

 

 

 

 

1. digital pid temperature controller Product Highlights

Thermocouple: T, R, J, B, S, K, E, Wre3-Wre25.

Thermo Resistor: Pt100, Cu50.

1 Relay output, 1 SSR controlled output.

Time proportional PID controlled output to either Relay or SSR

Three built-in algorithms that fit most control objects and various applications.

Temperature can be set to display in either Fahrenheit or Celsius degrees.

 

 

 

2. digital pid temperature controller Specifications

Supply voltage: 12V AC or DC

Power consumption: < 2 Watts.

Sampling speed: 4/sec.

SSR activated voltage: open circuit: 10V; short circuit: 40mA.

Accuracy: 0.2% of full scale.

LED Display: Red, 0.28 inch

Out of range indication: EEEE.

Ambient temperature requirements: 0 to 50 C (32 to 122 F)

Humidity requirement: < 85% RH.

Relay Contact: 220VAC, 3A.

Controller dimensions: 48 x 24 x 75 (mm).

Opening for installation: 44 x 20 (mm)

3. Panel Illustration and Description

 

1 -- AL, Relay J1 Indicator.

2 -- Select next parameter / value increment.

3 -- Selection previous parameter / value decrement.

4 -- Digit select / Auto tuning.

5 -- Setting / Confirm.

6 -- Output, controlled output indicator. (AT) Blinking during auto-tuning process.

7 Temperature reading, degrees F or degrees C (as chosen)

4. Parameter Setting

a) Press (SET) to enter setting mode.

b) Press (>), (v) and/or (^) to enter and select parameters.

c) Press (SET) again to confirm entry or selection.

 

i.) To enter initialization parameter setting mode press (SET), then enter code 0089, press

(SET) again.

Table 1 - Initialization Parameters

 

Symbol

Description

Range

Default

Setting

Comment

Inty

Temperature Sensor Type

See table 2

Pt100

 

  

Outy

Method of controlled

output

0,1,2

2

 

Note 1

 

CAty

PID algorithm

0,1,2

0

 

Note 2

PSb

Temperature Sensor

Correction

-100 to +100

degrees F, C

0

 

  

rd

Heating = 0;Cooling = 1

0,1

0

 

  

CorF

Celsius =0;Fahrenheit = 1

0,1

0

 

  

End

Exit

    

 

Table 2 - Temperature Sensor T ype

Symbol

Description

Range

Comment

 

t

T Thermocouple

-270 ~ 400 C

Internal Resistant

r

R Thermocouple

-50 ~ 1768 C

Internal Resistant

J

J Thermocouple

-210 ~ 1200 C

Internal Resistant

WrE

WRe Thermocouple

0 ~ 2300 C

Internal Resistant

 

b

B Thermocouple

0 ~ 1820 C

Internal Resistant

S

S Thermocouple

-50 ~ 1768 C

Internal Resistant

K

K Thermocouple

-270 ~ 1372 C

Internal Resistant

E

E Thermocouple

-270 ~ 1000 C

Internal Resistant

P10.0

P100 Thermo Resistor

-2.000 ~ 6.000 C

onstant Output

 

P100

Pt100 Thermo Resistor

-200 ~ 600 C

onstant Output

 

Cu50

Cu50 Thermo Resistor

-500 ~ 1500 C

onstant Output

 

 

Note 1:

0: Relay J1 Alarm output; SSR Disabled, normally used for upper lower limit alarm trigger control.

1: Relay J1 PID controlled output: SSR Disabled. Contact controlled output.

2: Relay J1 as alarm output; SSR PID controlled 12 Volt output. No Contact controlled output.

Note 2:

This controller has 3 types of auto-tuning control methods already built-in:

0: Universal PID control suitable for increase/decrease fast speed of change of temperature

application.

1: Gradual change PID control is suitable for applications that require steady change of

temperature and speed of temperature change is not critical.

2: Fuzzy logic control suitable for system with oscillation and sensing signal delay.

 

 

FAQ

1. Payment ways?

T/T, PAYPAL, WESTERN UNION.

2. When will you arrange the production?
In 12 hours since we get your payment.

3. What is your main products?
Thermocouple, PT100 sensor, termperture controller, infared thermometer and so on.

4. Product certifications?
ISO9001, CE, ROHS, FDA, SGS and other certificates.

5. What kind of informations shall I give you regarding the shipping?
Company name, Recipients, Correct Address, telephone, zip code.

6. What is your warranty ?
For most of our products, the warranty will be 12 months.

7. When will I get a solution for defective products?
Within 48 hours (on working days )

8. What is your shipping way?
DHL, FEDEX, UPS, TNT, EMS, CHINA POST AIR, SEA FREIGHT and AIR FREIGHT!

9. What is your shipping time?
For General Orders, the shipping time will be 5 workdays.

 

 
Shanghai Jiutian Automation Equipment Co., Ltd  has a specialized R&D team, whose specialized members have over- ten- year experience in thermocouple manufacturers field. It is water-resistant and rust-resistant. Shanghai Jiutian Automation Equipment Co., Ltd keeps consistency concurrent with the latest trends in the market. It is water-resistant and rust-resistant.
Product Message
Chat Online 编辑模式下无法使用
Chat Online inputting...